VA-3000 Series
10Pages

{{requestButtons}}

Catalog excerpts

VA-3000 Series - 1

VA-3000 Series / VS-3000 Series 06 Wide Variety of Standard Features and Functions as well as Optional Features. Allow the VA-3000 to be Configured to Meet the Requirements of Any Application. Standard functions configured prior to shipment include: Atmospheric Pressure Correction: Select 0-1VDC or 4-20 mA for each of two channels per module VA-3000 Series Other Optional Features: Output: Multi-Component Gas Analyzer The pressure compensation function corrects the output signal from the NDIR and MPA O2 modules for changes in sensitivity caused by changes in the atmospheric pressure since the instrument was last calibrated with a cylinder calibration gas. Galvanic, PMA and Zirconia O2 modules and the CLD module do not have pressure compensation. This option is useful if you desire the best possible accuracy over a period of time when you will not calibrate the instrument with cylinder gas. Communication Ports: One of two RS-232 may be changed to RS-485 Automatic Calibration: Activate this function to allow the instrument to reset the zero and span calibrations when the instrument is manually or remotely put in the calibrate mode. Select Automatic Range Change: Allows the user to set a point where the analyzer will automatically change from the measurement range it is currently on to the next highest or lowest range available in the analyzer module depending on whether the measured concentration is increasing or decreasing. Select Negative Display: Negative measurement value means you will never see any value on the screen less than 0.000. Select O2 Correction: If an O2 module is installed in the instrument case with other modules such as CO and NOx and if this function is activated, the measured values for CO and NOx will be corrected for dilution based on the measured O2 concentration in accordance with US EPA procedures. The instrument will have analog and digital (if communication options are installed) outputs for both the raw CO and NOx values as measured and the corrected values. Select the Concentration HOLD Function: If this function is activated, when the instrument is put into the zero or span calibration mode, the concentration values indicated at the analog outputs and any digital outputs (if additional communications options are installed) will be held at the concentration value last measured before the instrument mode was changed. Set Alarms for the Gas Concentration: There are two alarm points that can be set for each analyzer module. These can be set to alarm at a Low (zero) and a High value, or at a High and a Higher value. The alarm will show on the instrument front panel screen and will transmit information via the RS-232 port and if the optional PIO board is installed, contact closures are also available. Select Memory of Calibration and Alarm History: The processor in the instrument stores the zero and span calibration coefficients for each module installed in the case for 15 days. This information can be displayed on the front panel to indicate if there is a significant trend in calibration shift that would indicate that there might be a problem with the analyzer module. The processor also stores the last 30 analyzer alarms that occurred for each module installed in the case. This information can be displayed on the front panel. Rack-Mounted Sample Gas Conditioning Systems VS-3000 Series Flow Rate Display: A miniature mass flow meter is installed to monitor the flow rate of gas through the instrument. The flow rate is displayed on the front panel and if the flow rate deviates from a preset value an alarm will be displayed on the front panel and, if the VA-PIO-01 board or other communication options are installed, will be transmitted external to the instrument. Stainless Steel Tubing with Swaglok Fittings Stainless Steel Tubing and Swaglok Fittings can be provided as an option when the instrument is initially delivered. This option cannot be easily added at a later date. This option is not available for the CLD or O2 analyzer modules at this time. Separate Gas Inlet Fittings per Module: In the standard instrument, gas flows to the three modules sequentially in series. As an option HORIBA can make separate gas inlet connections for each module with a common exhaust; however, the software is designed so that all three modules will be in the zero calibration mode simultaneously and this cannot be changed. The span calibration may be done separately. Gas Connections on the Front Panel: The gas connections can be moved from the rear of the case to the front panel but if this is done then only two analyzer modules will fit into the standard VA-3000 case. HORIBA continues contributing to the preservation of the global environment through analysis and measuring technology. Please read the operation manual before using this product to assure safe and proper handling of the product. G The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company. G The color of the actual products may differ from the color pictured in this catalog due to printing limitations. G It is strictly forbidden to copy the content of this catalog in part or in full. G All brand names, product names and service names in this catalog are trademarks or registered trademarks of their respective companies. http://www.horiba.com G HORIBA, Ltd. Head Office Miyanohigashi, Kisshoin Minami-ku, Kyoto, Japan Phone: 81 (75) 313-8123 Fax: 81 (75) 321-5725 e-mail: info@horiba.co.jp Tokyo Sales Office 1-7-8 Higashi-Kanda Chiyoda-ku, Tokyo, Japan Phone: 81 (3) 3861-8231 Fax: 81 (3) 3861-8259 Alarms recorded include: Zero/ Span Calibration alarm, Cell Temperature and Chopper alarm for NDIR, Detector Temperature alarm for CLD module. G HORIBA INSTRUMENTS Pte. LTD. 10 Ubi Crescent #05-11/12, Ubi Techpark Singapore 408564 Phone: 65 6745-8300 Fax: 65 6745-8155 G HORIBA EUROPE GmbH Head Office Hans-Mess-Str.6 D-61440 Oberursel/Ts. Germany Phone: 49 (6172) 1396-0 Fax: 49 (6172) 137385 Bulletin:HRE-2854C G HORIBA INSTRUMENTS INCORPORATED Irvine Facility 17671 Armstrong Avenue Irvine, CA 92614, U.S.A. Phone: 1 (949) 250-4811 Fax: 1 (949) 250-0924 Leichlingen Facility Julius-kronenberg Strasse D-42799 Leichlingen Germany Phone: 49 (2175) 8978-0 Fax: 49 (2175) 8978-50 G HORIBA TRADING (SHANGHAI) CO., Ltd. Beijing Office Shanghai Office Room 1701, United Plaza, 1468 Nanjing Rd. West, Shanghai, 200040, China Phone: 21-6289-6060 Fax: 21-6289-5553 G HORIBA GmbH Kaplanstrasse 5 A-3430 Tulln, Austria Phone: 43 (2272) 65225 Fax: 43 (2272) 65230 G HORIBA KOREA Ltd. 112-6 Sogong-Dong Choong-ku, Seoul, Korea Room 1801, Capital Tower Beijing, Tower 1 No.6Jia, Jianguomenwai Ave., Phone: 82 (2) 753-7911 Fax: 82 (2) 756-4972 Chaoyang District, Beijing, 100022 China Phone: 10-8567-9966 Fax: 10-8567-9066 HORIBA CZECHIA Organizachi slozka Praha Petrohradska 13 CZ-101 00 Praha 10, Czech Republic Phone: 420 (2) 717-464-80 Fax: 420 (2) 717-470-64 G HORIBA INSTRUMENTS LIMITED Kyoto Close Summerhouse Road Moulton Park, Northampton NN3 6FL, U.K. Phone: 44 (1604) 542500 Fax: 44 (1604) 542699 G HORIBA FRANCE 12, Avenue des Tropiques 91955 LES ULIS France Phone: 33 (1) 69-29-96-23 Fax: 33 (1) 69-29-95-77 Printed in Japan ZY-F(SK)33

Open the catalog to page 1

All HORIBA Process & Environmental catalogs and technical brochures

  1. LA-350

    4 Pages

  2. LA-960

    10 Pages

  3. HT-110_TOC

    2 Pages

  4. LAQUAtwin

    6 Pages

  5. LAQUA series

    20 Pages

  6. CODA-500

    1 Pages

  7. 51 series

    2 Pages

  8. B-340 series

    2 Pages

  9. IG Series

    4 Pages

  10. TW-100

    4 Pages

  11. INM-700

    4 Pages

  12. ENDA-4000

    2 Pages

  13. PA-1000

    2 Pages

  14. IG-410

    2 Pages

  15. U-50 Series

    8 Pages

  16. AP-370 Series

    12 Pages

Archived catalogs

  1. B-700series

    5 Pages