Data transfer and import/export of sample informationcompatible with LIMS or third party software Results exporting and/or printing in real time, throughbatch reprocessing or on a sample-by-sample basis Wide range of industry compliant reports, as well asadditional reports such as stability report Full data archiving capabilitiesDiagnostics of the instrument can be performed in diffe-rentways : TimeScan, transient signal acquisition (real-time outputof instrument signal for troubleshooting or optimisation) Automatic export and calculation of parameters fromFigures of Merit measurements Remote control and PlasmaCam remote plasma viewingfor Service assistance SPC (Statistical Process Control) for X, R, SD andhistograms charts of user selected solutionsThe ACTIVAnalyst software is FDA 21 CFR Part 11compliant, with electronic signature of a dedicated
results report.
ICP-OES ACTIVA-M - 25366 The Art of CCD-based ICP-AESACTIVAnalyst software, to operate the instrument atits bestAs a whole, the strong interaction between instrumental configuration and software tools is the essence of this revolutionary approach. ACTIVA-M offers an incom- parable and practical use of multi-line analysis, regard-less of the expertise of the user. The instrument is usedat its best through time saving and user-friendly step- by-step operations. Everyone can easily become an expert in ICP analysis. Available in multi-language versions, the software provides a practical use for first-time operators, as well as optimisation capabilities for trained users.Some software functions are keys to a secure multi-useroperation of the instrument: on-line laboratory note- book; multi-user and multi-level security (biometric signature log-on available); computer programmable plasma conditions by method.First-time users quickly become confident throughassistance functions along the analytical methodology process: IMAGE for automatic semi-quantitative analy- sis; MASTER for lines selection; a Database of matrices, wavelengths and spectroscopic data, quality controls, sample tolerance tables and standards; optimization of integration time for each element based on sensitivity, speed and precision criteria from user’s input; SOS for evaluation of results.High sample throughput is achieved with the auto-sam-pler (benefiting from bar code identification of samples) and with automated analysis using a multi-method sequence for samples of various matrices requiring dif- ferent methods. Programmable calibration re-sloping and QC checks, with user-defined actions, ensure the automatic sequence processing, and the SOS tool gua- ranties the quality of results. The ICP system offers increased productivity through automatic user program- mable start up and shutdown. This also minimizes argon gas consumption. Urgent samples can be easily inserted at any time in a sequence in-run, using either the current method or other methods.Analytical criteria (accuracy, repeatability…) can beoptimised if required using various correction methods: controlled Standard Addition Method; automatic calcu- lation of additive and multiplicative Inter-ElementCorrection factors; Internal Standard correction; auto- dilution process; drift correction & high precision data processing; results reprocessing after calibration or pa- rameters changes.The simultaneous measurement allows visualising thespectra of lines and their vicinity during analysis for confirmation or identification of unexpected spectral interferences.Results are fully utilised through :IMAGE, MASTER,CALSTATand SOS are majortools for methoddevelopment,validation androutine analysis. 6 7 |
|