Type range -OPzVpower.bloc OPzVpower.com SBpower.com HCnet.powersolar.blocdry.powervalve regulated products

Standby - Overview - 15196 Standby Standby

Short description

Standby Batteries Standby Batteries

Standards DIN40742, IEC896-21/22DIN40744, IEC896-21/22IEC 896-21/22IEC896-21/22IEC896-21/22, BS 6290-4IEC 896-21/22 IEC896-21/22, BS 6290-4

Product overview Product overview

Capacity range in Ah200 - 3.00050 - 30050 - 14035 - 15180 - 15058 - 200 Ah7.2 - 200 Nominal voltage range2 V6 V, 12 V12 V12 V12 V6 V, 12 V12 V Container material (UL 94-V0 on request)SANPP, talcumPP, talcumPP, talcumABS, UL 94-VOPPABSGrid alloyPositivePb + <1% CaPb + <1% CaPb + <1% CaPb + <1% CaPb + <1% CaPb + <1% CaPb + <1% Ca NegativePb + <1% CaPb + <1% CaPb + <1% CaPb + <1% CaPb + <1% CaPb + <1% CaPb + <1% CaPositive plateTubularTubularGridGridGridGridGrid Negative plateGridGridGridGridGridGridGrid ElectrolyteH
2 SO
4 -GelH
2 SO
4 -GelH
2 SO
4 , fixed in AGMH
2 SO
4 , fixed in AGMH
2 SO
4 , fixed in AGMH
2 SO
4 , fixed in AGMH
2 SO
4 , fixed in AGMApplications Connector designFully insulated bolted connectorFully insulated bolted connector Fully insulated bolted connector Fully insulated bolted connectorFully insulated bolted connectorcramp connector, bolted connectorbolted connector / Faston Current behaviour
^=excellent^=good Design life up to (in years) 18151210 - 12126 - 93 - 5 Cycles up to1.2001.000700Charging voltage in V/cellFloat charge2.252.252.252.252.252.252.25 Boost charge2.402.402.402.402.402.402.40Float charging current / 100 Ah nominal capacity (20°C, U
float =2.23 / 2.25 V/cell)20 - 50 mA20 - 50 mA10 - 40 mA10 - 40 mA10 - 40 mA10 - 40 mA10 - 40 mA Position independent operation possibleYes, 1500 AhYesYesYesYesYesYesWater-refilling intervals in years at permanent float-charging/with AquaGen -------Self discharge of nominal capacity at 20°C ambient temperature/per month2 - 3%2 - 3%2 - 3%2 - 3%2 - 3%2 - 3%2 - 3% Operating temperature range in °C-20 - +40-20 - +40-20 - +40-20 - +40-20 - +40-20 - +40-20 - +40Ventilation requirementVRLA regulation; EN50272-2VRLA regulation; EN50272-2VRLA regulation; EN50272-2VRLA regulation; EN50272-2VRLA regulation; EN50272-2VRLA regulation; EN50272-2VRLA regulation; EN 50272-2 Storage time at 20°C before refreshing charge6 months6 months6 months6 months6 months6 months6 monthsType of thread for all types M8 (exception dry.power)
HOPPECKE Batterien GmbH & Co. KG Key: Emergency Power Engine StartPower Plant Power SupplyRailSignal towerSolarSwitch GearTelecom Transformer StationUPS P.O.Box 1140 · D-59914 Brilon Bontkirchener Straße 1 · D-59929 Brilon-Hoppecke Phone +49 2963 61-0 ·Fax +49 2963 61-270 www.hoppecke.com · info@hoppecke.com Standby Batteries product overview EN/07.2006/3 K Printed in Germany All details in this brochure are based on state-of-the-art technology. Our products are subject to constant development. We therefore reserve the right to make changes.