Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch - #1

/ 8


catalogue search
Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch
P. 01
Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch
P. 02
Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch
P. 03
Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch
P. 04
Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch
P. 05
Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch
P. 06
Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch
P. 07
Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch
P. 08
Pages:
Vortex Flow Sensor VA40 ZG8 Ex-d - U346 - Höntzsch


See other catalogues for Höntzsch

Text version of the page
1/8 Vortex Flow Sensor VA40 ZG8 Ex-d U346_VAZG8Exd_DoP_e_081020 http://www.hoentzsch.com Vortex probe VA for flow measurement of gases with integrated, configurable transducer UVA in Ex-d housing Functional principle • vortex meter for measuring flow velocity, flow rate and volume • ultrasonic measuring of the vortex shedding Advantages • compact measuring instrument with optional on-site display in Ex-application • application in category 1 (zones 0 and 20), transducer housing approved for category 2 (zones 1 and 21) • no external isolation/supply unit necessary • minimal reaction time (0.5 m/s) • high measuring dynamics (1:80) • steady long-term measuring • no moving parts • easy to clean • high fatigue strength • corrosion resistant • operates to a large extent irrespective of gas composition • minor pressure drop • easy configuration via HART.- interface Medium • primarily single-phase gas mixtures with air, nitrogen, oxygen, methane, natural gas, ammonia, argon, carbon monoxide, superheated steam ... as dominant components, biogas. Other gases or gas mixtures on request. Measuring range • 0.5 ... 40 m/s Measurable variables • actual flow velocity v [m/s] • actual flow rate [m3/h] in • conversion to standard velocity/standard volume flow by entering working pressure and temperature parameters Drawing 8 Design • insertion probe with probe guide piece and Ex-d housing Particles, humidty and condensation • charges in the gas caused by particles such as dust and fibres do not affect measurement, as long as abrasion and agglomeration do not occur on the sensor • relative gas humidity of less than 100 % and slight condensation on the sensor do not affect the measurement uncertainty Kármán vortex street Examples of application • flow measurement in Exapplication, for example, of air, outgoing air, sludge activation air, engine intake air, natural gas, exhaust gas, process gas, biogas, motor car exhaust, torch gas, water vapour Probe, as an example, with screw thread probe guide piece SFB Probe VA40 ZG8 as an example with flange guide piece SFB probe guide piece SF

pageCatalog pdf di En 2012-02-07-15