Thermal Flow Sensor TA10 ZG2b - U314 - Höntzsch - #1

/ 6


catalogue search
Thermal Flow Sensor TA10 ZG2b - U314 - Höntzsch
P. 01
Thermal Flow Sensor TA10 ZG2b - U314 - Höntzsch
P. 02
Thermal Flow Sensor TA10 ZG2b - U314 - Höntzsch
P. 03
Thermal Flow Sensor TA10 ZG2b - U314 - Höntzsch
P. 04
Thermal Flow Sensor TA10 ZG2b - U314 - Höntzsch
P. 05
Thermal Flow Sensor TA10 ZG2b - U314 - Höntzsch
P. 06
Pages:
Thermal Flow Sensor TA10 ZG2b - U314 - Höntzsch


See other catalogues for Höntzsch

Text version of the page
Functional principle • measurement of flow according to heat transfer method • temperature dependence of measurement compensated by complete temperature operating range Gases • pure gases, gas mixtures: air, nitrogen, methane, natural gas, argon, carbon dioxide, helium, sulphur hexafluoride, landfill gas ... • a calibration with a multitude of gases or gas mixtures can be carried out to achieve the slightest measuring uncertainty Advantages • high measuring dynamics Nv (up to 1 : 1000) • measuring range from 0.2 m/s • low measuring uncertainty, even at lowest flow velocities • direct air/gas mass flowproportional measuring. Additional measuring of pressure and temperature not necessary • sensor has no moving parts • stainless steel sensor housing • greater working temperature and pressure ranges • low installation costs • low pressure drop due to small dimensions • long life • sterilisable (sensor materialresistance allowing) • optional, double-spaced LCD: volume flow / counter • parameterization and optimal integration with PC software Particles, condensation, humidity in the gas • charges in the gas caused by particles such as dust and fibres do not affect the measurement, as long as abrasion and agglomeration do not occur on the sensor • deviations in values as a result of variable air humidity in normal atmospheric conditions are covered by the measuring uncertainty specifications Range and examples of application • measuring - air velocity - compressed air and gas consumption, leakage - laminar flows in clean rooms or machines - in outgoing air, burner supply air and draughts - in climatic applications - in air in rough vacuum range with pressures greater than 200 hPa abs. Measurable variable • standard velocity Nv, standard volume flow NV/t, mass flow proportional • norm: temperature tn = +21 °C, pressure pn = 1014 hPa U314_TA10ZG2b_DoP_e_090730 http://www.hoentzsch.com 1/6 Thermal Flow Sensor TA10 ... ZG2b Sensor TA10 ... ZG2b with integrated transducer U10a TA10 ... ZG2b (Meas. A Page 2) Design Probe with integrated transducer Drawing 2b

pageCatalog pdf di En 2012-02-07-15