Group: Honeywell
Catalog excerpts
c€ Thermal equipment trip TAS Manual valve with thermal equipment trip AKT..TAS • Isolate the gas pipeline in the event of a fire • High thermal capacity • AKT..TAS: two fittings in one housing • EC type-tested and certified Product brochure ■ GB 1 Edition 05.141
Open the catalog to page 1TAS: the thermal equipment trip shuts off pipelines safely up to 650°C. Thermal equipment trips can be used in industrial and commercial installations, upstream of gas inlet systems, at gas cooker points, instantaneous water heaters and gas boilers. In the event of fire, they isolate the gas pipeline and provide long-term protection against the uncontrolled escape of gas and a potential explosion. Valves AKT..TAS and TAS can be used pursuant to the German Firing System Directive and TRGI (DVGW Code of Practice G 600). AKT..TAS: the spacesaving combination of a manual valve and a thermally...
Open the catalog to page 2Kitchen safety equip men t with AKT.R10TA S/A KT. R40TAS Examples of application When a thermal equipment trip TAS or a manual valve with thermal equipment trip AKT..TAS (pursuant to TRGI) is installed, the gas safety system features enhanced fire protection. If the ambient temperature increases to more than 95°C in the gas pressure control (and measurement) system, the thermal equipment trip TAS trips and shuts off the gas supply safely. In the application kitchen safety equipment with AKT..R10TAS/AKT..R40TAS and main gas shutoff device with AKT..F50TAS, the gas supply can be shut off...
Open the catalog to page 3Technical data Types of gas: natural gas, town gas and LPG (gaseous). Fuel gases in accordance with DVGW Code of Practice G 260. Thermally controlled tripping at: 95°C, +/-5°C. Closing time: 60 s. Duration of seal (HTR): minimum 60 minutes at 650°C. Leakage: 30 l/h (at a test air pressure of 4 bar). Ambient temperature: -20 to +60°C. Thermal equipment trip TAS In acc. with DIN 3586. Inlet connection: Rp internal thread to ISO 7-1, PN 16 flanged connection to ISO 7005. Outlet connection: Rp internal thread and R external thread to ISO 7-1, PN 16 flanged connection to ISO 7005. Housing:...
Open the catalog to page 4All Honeywell Thermal Solutions catalogs and technical brochures
-
Thermal Solutions
12 Pages
-
COMBUSTION CATALOG
176 Pages
-
thermal IQ
4 Pages
-
Magnetic relief valves VAN
4 Pages
-
Tightness controls TC
12 Pages
-
Pressure switches for gas DG
4 Pages
-
Burners for gas BIC, BICA, ZIC
16 Pages
-
Valves and butterfly valves
8 Pages
-
E-SOLUTIONS FOR COMBUSTION™
4 Pages
-
Field bus interface PFA 700
28 Pages
-
Manual valves AKT
4 Pages
-
Gas Pressure Regulator GDJ
2 Pages
-
Gas Pressure Regulator VGBF
4 Pages
-
Safety shut-off valve
2 Pages
-
Relief valves
2 Pages
-
BV.., IB..
8 Pages
-
Gasfilter GFK
4 Pages
-
HTS Engineered to order
8 Pages
-
Training Brochure 2019
17 Pages
-
HONEYWELL COMBUSTION SERVICE
4 Pages
Archived catalogs
-
Solenoid Valves for air VR
16 Pages
-
GIKH
2 Pages
-
GIK
2 Pages
-
IFD 450, IFD 454
34 Pages
-
pb_j78r_60dj_gb
2 Pages
-
pb_tas_akt_tas_gb 2007
6 Pages
-
Gear motors GT
4 Pages
-
Actuators IC 20, IC 40
8 Pages
-
Burner control unit CM 222
4 Pages
-
Control valves S11T
4 Pages
-
Burner control unit BCU 370
6 Pages
-
Product range
4 Pages