video corpo

Pressure switches for air CPS
4Pages

{{requestButtons}}

Catalog excerpts

Pressure switches for air CPS - 1

Honeywell taper , schroder Pressure switches for air • Precision differential pressure switches • Monitoring of air and other non-flammable gases • High switching point stability • Switching point selection via hand wheel • Screw terminals for electrical connections • Flexible mounting options • ALL connections accessible from one side • CE and ROHS compliant Product brochure ■ GB 4 Edition 11.081

Open the catalog to page 1
Pressure switches for air CPS - 2

Easy-to-install connections, accessible from one side. Pressure switches for air CPS can be used as excess pressure, negative pressure and differential pressure switches for air and other non-flammable gases. They monitor extremely slight pressure differences and trigger switch-on, switch-off or switch-over operations if a set value is reached. Example applications Fields of application include air flow monitoring, fan monitoring or filter monitoring on intake and extract ventilation systems, on air-conditioning systems and in kitchens, frost-protection control on heat exchangers and...

Open the catalog to page 2
Pressure switches for air CPS - 3

Mounting without the need for tools or screws Optional S-clip for fast installation and removal of the pressure switch. Only two holes in the mounting plate or air duct are required for secure mounting. Rugged, locked mounting Optional, L-shaped or Z-shaped angle bracket for fast installation and removal with diverse mounting options, even with only one screw. The angle bracket increases the distance between pressure switch and mounting plate and protects against hot mounting plates. Clearer handling in complex ­installations Optional scale marking, e.g. for pressure switches with the same...

Open the catalog to page 3
Pressure switches for air CPS - 4

Type code Technical data Type Code Description (max. 5 A, at cos 9 0.6 = 1 A) CPS..G: 12 V (min. 0.01 A) to 250 V AC (max. 5 A, at cos 9 0.6 = 1 A) 12 V (min. 0.01 A) to 48 V DC (max. 1 A) If the CPS..G has switched a voltage > 24 V and a current > 0.1 A once, the gold plating on the contacts will have been burnt through. It can then only be operated at this power rating or higher power rating. Contact gap < 3 mm (p). Line entrance: M16 * 1.5. Enclosure to IEC 60529: IP 54. Safety class II to VDE 0106-1. Diaphragm: Tempered LSR diaphragm system. Max. inlet pressure pe or differential...

Open the catalog to page 4