Text version of the page
HOHNER AUTOMAZIONE SRL
Series
Electronics Data
EXH-EXHA
Power supply: from 5 to 28V depends on the electronics circuit Current consumption: 40/80mA depends on the electronics circuit Permissible load: 40mA Frequency: 600KHz (depends on the electronics circuit) Protections: Against short circuit, reversal polarity Operating Temp.: -20/+40°C Output signals (cw)
Ordering code
E X H
Series
E X HA
- *****.** /
Pulse
(Max 36.000) Shaft Flange Outputs Connections Variant
2 = Ø 12mm 1 = Ø 11mm only flange R 3 = Ø90mm R = Ø115mm 2 = AB PP11/28V 3 = AB0 PP11/28V N = AB+AB PP11/28V P = AB0+AB0 PP11/28V B = AB OC11/28V C = AB0 OC11/28V G = AB NPN 11/28V H = AB0 NPN 11/28V 5 = AB+AB LD5V 6 = AB0+AB0 LD5V 8 = AB+AB LD5/12V 9 = AB0+AB0 LD5/12V S = AB+AB LD15/24V(out 12V) T = AB0+AB0 LD15/24V(out 12V) K = AB0+AB0 LD15/24V(out 5V) J = AB+AB W= AB0+AB0 Sin.Version A = AB+REF max 3600 pulse Y = AB0+REF Standard 9 = Axial cable. 2mt 1 = Axial cable10mt Option 8 = Axial cable 2mt + Hawke 2 = Axial cable 10mt + Hawke xxx = Optional >
Option
0 = None 1 = High zero pulse Z = Synchronised zeroPulse to 180° only for Line Driver W= Synchronised zeroPulse to 90° only for Line Driver Y = Power supply 5/12V (only NPN OC,PP U = Power supply 5- 28V (only PP) >
EXH= Aluminium version EXHA= Steel version
Connections
0 Volt + Volt A B A B 0 0 Cable Black Blue Brown White Green Yellow Pink Violet >