Wall-Mount Disconnect Enclosures
Bulletin
Type 12 and Type 13 Enclosures for Flange-Mounted Disconnects
A Pentalr Company
A25
Features
• Includes latch pivot post(s) and cover interlock bracket welded to door, cover latch bar for door, and instructions for installing disconnects
• Models ending with PL include handle and latching hardware
Construction
• I4 gauge steel
• Seams continuously welded and ground smooth
• Bonding provision on door
• External mounting brackets
• Return flange around all sides of enclosure opening excludes liquids and contaminants
• Removable door with continuous hinge
• Data pocket is high impact thermoplastic
• Oil-resistant gasket
• Collar studs for mounting optional panels
• Holes in body and door for mounting operating handle, operating mechanism, and door closing mechanism
• Enclosures available with or without padlocking, defeater handle and latching system
Finish
White inside with ANSI 61 gray outside finish over phosphatized surfaces. Optional panels have white or conductive finish.
Industry Standards
UL 508A, File No. E6I997: Type 12, 13 NEMA/EEMAC Type I2, I3 JIC standard EGP-I-I967 CSA File No. 42I86: Type I2 IEC 60529, IP65
Accessories
See also Accessories chapter.
Blank Adapter Plate
Blower Package
Corrosion Inhibitors
Electric Heater
Fan Cooling Products
Handle Kit
Lighting Kit
Panel Support Kits
Panels
Touch-Up Paint (ATPHS6I) Window Kit Floor Stand Kits
Furnished with Enclosures
1. Latch pivot post(s) and cover interlock bracket welded to door
2. Cover latch bar for door hardware
3. Handle and latching hardware on models ending with "PL"
4. Instructions to locate and install disconnects
Ordering
Depending on model, order as follows: PL models:
• Disconnect switch or circuit breakers All other models:
• Disconnect switch or circuit breakers
• ASAHPDF Handle Kit —or—
• Operating handle,
• Operating mechanism, and
• Door hardware
See Technical Information in the Hoffman Specifier's Guide for wire bend space available when various manufacturers' disconnect switches are installed, or Disconnect Ordering Information at hoffmanonline.com for disconnect ordering guidelines and wire bend space available. Check the enclosure dimension drawings to verify the chosen disconnect switch will fit in the enclosure.
Modification Services Program
You can customize this product to your unique requirements by specifying from these options:
• Enclosure height, width, depth
• Over 100 standard finish colors and textures
• Holes and cutouts in body, doors, subpanels
• Tapped holes, fasteners in enclosure or subpanel
• Mounting
• Doors
• Environmental control (louvers, fans, filters)
• Windows
• Standard accessories
To order, contact your local Hoffman sales representative.
NOTE: For information about modifications outside the scope of the Modification Services program, contact your Hoffman sales representative.
Application
Designed to house the following:
Allen-Bradley
• Bulletin I494V-DSX series left-hand variable-depth disconnect switches with flange-mounted operating handles
• Bulletin I494V-C series left-hand variable-depth circuit breaker operating mechanisms with flange-mounted operating handles
These enclosures will NOT accept Allen-Bradley Bulletin I494V-DS right-hand variable-depth disconnect switches, Allen-Bradley Bulletin I494F disconnect devices, or Bulletin I494D circuit breaker operators. See Type 12 and 13 Enclosures for Allen-Bradley Disconnects in this section.
ABB Controls flange-mounted variable-depth operating mechanisms for disconnect switches and circuit breakers. Also the cable version for circuit breakers.
Eaton Cutler-Hammer Type C36I flange-mounted variable-depth operating mechanisms with disconnect switches and Type C37I flange-mounted variable-depth operating mechanisms for circuit breakers. Also Flex Shaft™ handle mechanisms for circuit breakers.
General Electric Type STDA flange handles and variable-depth operating mechanisms for disconnect switches and circuit breakers. Also Spectra Flex™ cable operators for circuit breakers.
Siemens ITE Max-Flex™ flange-mounted variable-depth operating handle for disconnect switches and circuit breakers as well as some fixed depth operators for disconnect switches.
Schneider Square D® Class 9422 left-hand variable-depth disconnect switches with flange-mounted handle mechanisms and Class 9422 variable-depth circuit breaker operating mechanisms.
These enclosures will NOT accept Square D Class 9422 bracket-mounted disconnect devices, Class 9422TGI, or TG2 devices.
b Catalog number A60SA3812A24LP enclosure will receive only 400 amp and 600 amp Allen-Bradley Bulletin 1494V disconnect switches, and Siemens ITE 800 amp and 1200 amp circuit breakers. The 400 amp and 600 amp Allen-Bradley disconnect switch will not fit any other size enxlosure from the Bulleting A25 family. Blank Adapter Plates will not fit catalog number A60SA3812A24LP.
c Enclosures 12 inches and 16 inches deep can be modified to accept Siemens ITE 800 amp and 1200 amp circuit breakers. (When using a Siemens ITE circuit breaker and an anclosure with an A dimension of 30-, 36-, or 42-inches, verify the amount of wire bend space required for both the line and load sides.) Consult factory for details.
d
Enclosure includes zinc diecast padlocking defeater handle and all latching hardware. Keylocking and pad locking only handles are available as a custom order.