You may also be interested in
Autocollimator, Calibration source, Infrared light source, Light source, Camera
Text version of the page
5Catalog - 7666 TECHNICAL DATARCN600 N05 RCN1200N1 RCN1200N2 RCN1400N1 RCN1600N2Aperture diameter (mm) : 12.5 25 30 40 Temperature range ( C) : 50 to 600 50 to 1200 300 to 1400 300 to 1600 Cavity uniformity ( C at 900 C ±3 C) : 2 C at 600 C ±4 C at 900 C ±2°C at 1600°C Temperature sensor type : Type K, class 1 Type S, class 1 Type S, class 1 Type R, class 1 Temperature sensor accuracy : ±1.5 C up to 375 C up to 375 C up to 1100C, ±(1+0.003(T-1100)) above ±1 C up to 1100C, ±(1+0.003(T-1100)) above Warm up time from ambient : 15 minutes to 600 C, ±0.4%T above ±1.5 C, ±0.4%T above ±1 C 40 minutes to 1200 C 60 minutes to 60 minutes to Maximum power consumption : 200 W 850 W 1800 W 4500 W 1800 W when Dimensions W x H x D (mm) : 160x137x170 193x219x405 392x363x496 540x482x601 Blackbody weight (kg) : 2 11 32 43 Electronic unit size : 4U x 19” 4U x 19” 4U x 19” 12U x 19” Electronic unit weight (kg) : 9 25 26 92 Emissivity : > 0.99 Regulation type : real time PID adjustment Stability : ±0.05 C Display resolution : 0.1 C (actual temperature and set point display) Power supply : 115/230 VAC, 1 ph., 50/60 Hz Remote control : USB interfaceAbove information is subject to changes without notice |
|