BMI F650 - Hexcel Corporation - #5

/ 12


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
Pages:


See other catalogues for Hexcel Corporation

Text version of the page
Cure Cycle
Hold 240
+ 10 min - 0 min
@ 375
10F
(191
6C)
Heat-up
/
v Cool-down
1-5F/min
/
5F/min
(0.6-3C/min)
/
/
/
* (3C/min) 1 . maximum
Hold 360
+ 10 min - 0 min
\ \-
@ 350
10F
- 0 min
\ \
(177
6C)
-Vent Bag
\ \
Hold 85 psi (586 kPa)
\ \
& 22 in (74 kPa) Hg
* \
@ 80-100F (27-38C)
\ \
for 30 minutes
\
375 (191)
o
il 350 (177)
ai
Q.
E
100 (38)
Time
Cure Procedure
A. Apply vacuum, 22 in. (74 kPa) Hg, and 85 psi (586 kPa) autoclave pressure at ambient temperature.
B. Hold at 80-100°F (27-38°C) for at least 30 minutes, then vent vacuum.
C. Raise temperature to "option."
I. 350°F at 1-5°F (177°C at 0.6-3°C) per minute and hold for 6 hours.
II. 375°F at 1-5°F (191°C at 0.6-3°C) per minute and hold for 4 hours.
D. Cool and remove from autoclave.
E. Postcure either 8 hours at 450°F (232°C) (recommended) or 4 hours at 475°F (246°C). Raise temperature from ambient to 375°F (191°C) at a rate of 5-10°F (3-6°C) per minute and a rate not to exceed 3.3°F (2°C) per minute above 375°F (191°C).

pageCatalog pdf di En 2012-02-07-13