Intelligent combina
7Pages

{{requestButtons}}

Catalog excerpts

Intelligent combina - 1

HENGYI ELECTRIC GROUP Intelligent combina�on low voltage power capacitor 1 General Working in a 0.4kv low voltage network, the intelligent reac�ve compensa�on installa�on (intelligent combina�on type low voltage energy-saving power capacitor) can reduce line power loss, correct power factor, improve power quality, energy-saving device. It combines advanced technologies like modern measurement and control, power electrionics, network communica�on, auto-control, and power capacitor. Compared with tradi�onal reac�ve compensa�on installa�ons, it is smaller, cheaper, more cost-saving, more flexible, more convenient to maintain, with less power consump�on, longer life span and more reliability, matched with demand of smart grid for reac�ve compensa�on. 2 Applicaton The capacitor compensa�on installa�on offers solu�ons to improve power factor and increase power grid efficiency. The main applica�on fields are: Factory power distribution systems Residential area power distribution systems Municipal commercial buildings Tunnel traffic power distribu�on systems Box transformer substa�on, cabinet sets, and outdoor distribu�on boxes HYBAGB )/- I Type (I: dry-type; none: regular) Second capacitor capacity First capacitor capacity Rated capacity Capacitor rated voltage Program code FB: Indicates split phase compensa�on GB: Indicates three phase compensa�on A: Automa�c control B: Design No. Enterprise code 4 Normal working and installa�on condi�ons 4.1 Ambient temperature:-25℃ ~ +55℃ 4.2 Rela�ve humidity:40℃ ≤20%;20℃ ≤90% 4.3 Al�tude:≤2000m 4.4 Environmental condi�ons: no noxious gas and vapour; no conduc�vity or explosive dust; no violent mechnical vibra�on. 5 Main parameters and other condi�ons HYBAFB-35H 35kA high breaking ability type 5.1 Measurement error Voltage:≤±0.5%,Current:≤±0.5%, Ac�ve power:≤±1%,Power factor:≤±1%,Temperature:±1℃ 5.2 Protec�on error Voltage:≤±0.5%,Current:≤±0.5%,Temperature:±1℃ ,Time:±0.1s 5.3 Reac�ve compensa�on parameters Reac�ve compensa�on error:≤Minimum capacitance 50%,Capacitor switching �me can be set between 10s~180s, 5.4 Reliability parameters Control accuracy: 100%,Permissible switching �mes: 1 million, A�enua�on ra�o of capacitance running �me: ≤1% per year, A�enua�on ra�o of capacitance switching: ≤0.1% per 10,000 �mes 5.5 Mains condi�ons: rated voltage:380V±20%; (other rated voltage produc�on on requested)。 Harmonic voltage: Sine wave, with tot

Open the catalog to page 1
Intelligent combina - 2

5.6 Executive standards: electric clearance and creep distance, insulating strength, safety protection, short circuit strength, sampling and controlling circuit all apply to the corresponding regulations stated in GB/T15576-2008 Low Voltage Combination Reactive Power Compensation Installation. HYBAGB-H three phase mixed compensation Compensation modes For example: HYBAGB-1 I 0/450/10(5+5), -EH EH: Program code

Open the catalog to page 2
Intelligent combina - 3

HENGYI ELECTRIC GROUP 7 Exterior and moun�ng size(mm) W L Note: moun�ng distance between two capacitors≥50mm 8 Figure of the product func�on equivalence HYBAFB-35H 35kA high breaking ability type

Open the catalog to page 3
Intelligent combina - 4

9 Connec�on diagram 9.1 Single unit connec�on diagram(split phase compensa�on type capacitor) UA S2 note: S2 to earth split phase compensation type Secondary current transformer split phase compensation type capacitor 9.2 Single unit connec�on diagram(three phase compensa�on type capacitor) UA three phase compensation type Secondary current transformer three phase compensation type capacitor 9.3 Connec�on diagram of three phase mixed compensa�on (without controller) split phase compensation type Secondary current transformer split phase compensation type capacitor split phase compensation...

Open the catalog to page 4
Intelligent combina - 5

HENGYI ELECTRIC GROUP 9.4 Connec�on diagram of three phase compensa�on (without controller) UA three phase compensation type Secondary current transformer three phase compensation type capacitor three phase compensation type capacitor three phase compensation type capacitor three phase compensation type capacitor note : three phase compensation type ≤ 32 sets 9.5 Connec�on diagram with JKGHY580 controller(three phase mixed or three phase compensa�on) S1 to "+" ; S2 to "-" and to earth S2 S2 split phase compensation type capacitor split phase compensation type capacitor three phase...

Open the catalog to page 5
Intelligent combina - 6

10 Examples of applica�on modes 10.1 Applica�on of on-site reac�ve compensa�on 10.2 Applica�on in compensa�on boxes like pole reac�ve compensa�on box. 10.3 Low voltage comprehensive power distribu�on box

Open the catalog to page 6
Intelligent combina - 7

HENGYI ELECTRIC GROUP 10.5 Applica�on in American-type and European-type box transformer substa�ons 10.6 Applica�on in inspec�on and extension 11 Accessories (op�onal) 11.1 Secondary current transformer Name three phase compensa�on type Corresponding type Secondary current transformer Three phase compensation type Split (mixed) compensa�on type Optional when Three phase compensation type intelligent capacitor is used as master Optional when split compensation type intelligent capacitor is used as master 11.2 Communicaton cable Type and specificaton W20 Connection of two neighboring...

Open the catalog to page 7

All Hengyi Electrical Co. catalogs and technical brochures

  1. HYSVG Sta

    4 Pages