| Remove the wires as described below under "Installation" only after the coiled Risk Of Injury spring has been fitted over the shaft! Safety information The coil spring must be used only together with the part to be protected, i.e. a ballscrew, etc., otherwise it can snap out unexpectedly and cause grievous injury! Conditions of use DURASPRING coil springs operate optimally in oily environments. In environments with fine particles or larger dust accumulations, e.g. from wood processing, bellows must be used instead. Warranties Our warranty for DURASPRING coil springs extends to material and production defects only. Our warranties do not extend to damage incurred as a result of improper installation, loading, and failure to service or clean, e.g. swarf accumulation. Our general terms and conditions are available as a download at www. hema-schutz.de 1. Installation ■ Before installing the coil spring ensure that the flanges on the machine have the tolerances specified in the catalogue. ■ The coil spring must be installed in accordance with the mounting label H (horizontal) or V (ver-tical).When installed vertically the spring's larger mounting diameter is uppermost. ■ The wires must not be removed until after the coil spring has been installed at its intended position and the flanges are about two to three coil strip widths apart. ■ Remove all of the wiring. ■ After removing the wiring insert the coil spring carefully into the flange receiver. Do not let the coil spring snap out! ■ Note: When installed DURASPRING coil springs must move freely and must not be screwed or riveted! |