You may also be interested in
Power distribution cable, Cable protection conduit, Rack cabinet, Braided sleeving, Hook-up wire
Text version of the page
These robust special rubber sheathed cables can be used where high demands are placed on temperature range,
flexibility and mechanical stress.
For application on construction sites, in steel works and rolling mills in heating and air-conditioning systems, in
the bottling industry, in machinery and plant construction, in the chemical industry and painting systems, as well
as for the professional and the hobby enthusiast.
The choice of yellow as the sheath colour ensures additional safety.
Can be used in potentially explosive areas acc. to DIN VDE 0165.
Resistant to: Atmospheric influences, ozone, hydrolysis, UV-radiation, largely resistant to oils and fats
Special features: High flexibility at low temperatures, increased stability and tear-resistant
®
www.helukabel.de
Technical data
. Special rubber sheathed cable acc. to
DIN VDE 0282 Part 4, HD 22.4 S3
. Temperature range
flexing –25°C to +100°C
fixed –50°C to +100°C
. Permissible operating temperature at
conductor +90°C
. Nominal voltage
U /U 450/750 V 0
with protected fixed installation
U /U 600/1000 V 0 . Highest permissible operating voltage in
three-phase and one-phase a.c. systems
U /U 476/825 V 0
in d.c. systems U /U 619/1238 V 0 . Test voltage 3000 V
. Minimum bending radiusflexible
up to 12 mm cable , 3 x cable
Greater than 12 mm cable , 4 x cable
O/ O/
O/ O/
Application
. Flame-retardant acc. to DIN VDE 0482,
Part 265-2-1/ EN 50265-2-1/ IEC 60332-1
(as per DIN VDE 0472, Part 104 Test
Method B)
. High flexibility at low temperatures
. Increased stability
. Resistant to
Atmospheric influences, Ozone,
Hydrolysis, UV-radiation
. Largely resistant
to oils and fats.
. The materials used in manufacture are
cadmium-free and contain no silicone
and free fromsubstances harmful to the
wetting properties of lacquers
Construction
. Bare copper conductor, fine wire to DIN
VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228
cl. 5 and/or HD 383
. Rubber core insulation, EPR/EPDM
adapted to DIN VDE 0207 part 20
. Core identification to DIN VDE 0293
. Core colours
. up to 5 cores one-coloured
. 6 and more cores, black with
numbering
. 3 cores and above with
green/yellow earth core
. 2 cores without green-yellow
earth core
. Cores stranded in layers with optimal
lay-length
. Special outer sheath, cross-linked
. Sheath colour Yellow (RAL 1021)
. Flame-retardant acc. to
DIN VDE 0482, Part 265-2-1/ EN 50265-
2-1/ IEC 60332-1
(as per DIN VDE 0472, Part 104 Test
Method B)
Note
G= with green-yellow earth core
X= without earth core (OZ)
ex e t w t s fl ibl a lo emperature ,
- si n wear re sta t, robust
The robust special rubber sheathed
cable for high mechanical requirements
|
|