| | | Flap Flow Meter TSK Applications: Flow measurement of liquids Product specialities: Can be used for vertical and horizontal installation. Reliability Robust construction with magnetic transmission of measured values. Wide and clear scale Special materials Hastelloy, PTFE, or PP Can be used in hazardous areas | | |
| | | |
| | | Technical data: Range: Nominal sizes: Nominal pressure: Process temperature: | | |
| | | 1,5 m3/h ... 1.200 m3/h DN50 ... DN500 in sandwich structure up to PN 100 -20°C ... +300°C | | |
| | | |
| | | |
| | | Options: Display unit in stainless steel, IP 68 Electronic transmitter ES Limit switches | | |
| | | |
| | | Communication: HART® Profibus | | |
| | | |
| | | Electronic Transmitter ES Can be used in the following devices, BGN, BGF, TSK (flow metering), DWF (density metering), BA (level metering). Product specialities: Reliability The transmitter can be replaced without recalibration. 2-wire system Application possible in hazardous areas Linearization of the characteristic with 16 fulcrums Technical data: Current output 4 - 20mA Explosion protection, ATEX: intrinsically safe | | |
| | | |
| | | Options: Digital display Limit switches acc. to NAMUR (software-controlled) Pulse output | | |
| | | |
| | | Communication: HART® Profibus | | |
| | | |
| | | | | | | | | | | | | | |