Areas of application: Flow measurement of conductive liquids

Product overview - 25107 Magnetic-Inductive Flow Meters EP, PIT, PITY

Applications: Volume flow measurement Product specialities: ReliabilityDifferent materials for electrodes (e. g. Hastelloy, Platinum, Tantalum, Gold, and many more.)Tailor made solutions. Transmitter UMF (to be used in hazardous areas)Transmitter UMF2

EP PIT, PITY

Inline sensor with linings made of PFA, PTFE, hard rubber Insertion type MAG meter as an alternati- ve to classic inline MAG flow meters. Technical data: Nominal size: DN10 ... DN600 Nominal pressure: up to PN 40 Range: 0,0015 m Technical data: Range I0.5 m/s ... 5 m/s Range II1 m/s ... 10 m/s Nominal pressure: up to PN40 Accuracy: ±1,5% of reading ±0,5% ofmax. range Appropriate for nominal sizes up to 2.000 mm. Options: Retractable during operation
3 /h ... 10.000 m
3 /hViscosity: 0,2 mPas ... 50.000 mPas Process temperature: -25°C ... +180°C Accuracy: ±0,5% of measuring value Options: Different nominal size, pressure rating and ranges on request!

Transmitters UMF and UMF2 for Magnetic-Inductive FlowMeters

Technical data: Communication:

Transmitter UMF Transmitter UMF2

1 current output 0/4 - 20mA 1 pulse output 1 status output HART Easy to handle digital transmitter for magnetic-inductive sensors of the seriesEP, PIT and PITY. Technical data: Product specialities: 1 current output 0/4 - 20mA 1 pulse output, 1 status output Easy to handle digital transmitter for magnetic-inductive sensors of the series EP, PIT and PITY. The electronic transmitter can be mounted integral or remote. The transmitter can be replaced without recalibration. Digital on-site display (with illuminated background) Product specialities: Options: Can be used in hazardous areas The electronic transmitter can be mounted integral or remote. The transmitter can be replaced without recalibration. DSB data memory module The display/interface board can be instal- led separately. Approval: Explosion protection, ATEX: intrinsically safe, explosion proof, increased safety NEPSI (applied for) Communication: HART
® ®

pageCatalog pdf di En 2012-02-06-12