IncrementalERO 1225ERO 1285Incremental signals TTL 1 V >
PP Line count * 1 0242 048System accuracy >
1) /Accuracy of the graduation >
2) 1 024 lines: ± 92"/± 6" 1 024 lines: ± 67"/± 6" 2 048 lines: ± 73"/± 6" 2 048 lines: ± 60"/± 6"Reference markOneScanning frequencyEdge separation 300 kHz Typically 180 kHz a 0.39 µs––– Power supply Cutoff frequency –3 dB 5 V ± 10 % Current consumption 150 mA without load
Electrical connection Via 12-pin
Pcb connector Shaft* Hollow through shaft 10 mm or 12 mm Moment of inertia of rotor Shaft 10 mm: 2.2 · 10 >
–6 –6 kgm >
2 Shaft 12 mm: 2.15 · 10 kgm >
2 Mech. permissible speed n 25 000 min >
–1 Permissible axial motion of measured shaft 1 024 lines: ± 0.2 mm 2 048 lines: ± 0.05 mm± 0.03 mm Vibration 55 to 2 000 Hz 100 m/s >
2 2 (EN 60 068-2-6) Shock 6 ms 1 000 m/s (EN 60 068-2-27) Max. operating temp. 100 °C Min. operating temp. –40 °C Protection EN 60 529IP 00 Weight (approx.) 0.07 kg >
1) * Please indicate when ordering >
2) Before installation. Additional errors caused by mounting inaccuracy and inaccuracy from the bearing of the drive shaft are not included. For other errors, see Measuring Accuracy >
49