AbsoluteECI 1319 >
1) EQI 1331 >
1) Incremental signals 1 V >
PP Line count/System accuracy32/± 280"Cutoff frequency –3dB 6 kHz typical Absolute position values >
1) EnDat 2.1Ordering designationEnDat 01
Position values per rev524 288 (19 bits)Revolutions–4 096 (12 bits)Elec. permissible speed/Deviations >
–1 –1 2) 3 750 min >
–1 /± 128 LSB 3 750 min >
–1 /± 128 LSB 15 000 min /± 512 LSB 12 000 min /± 512 LSBCalculation time t >
cal 8 µs Power supply* 5 V ± 5% or 7 to 10 V Current consumption 170 mA without load
Electrical connection Via 12-pin
Pcb connector Shaft*/Moment of inertia 9.25 mm; Taper 1:10 /2.2 x 10 >
–6 –6 kgm >
2 of rotorTaper shaft Blind hollow shaft 12.0 mm; Length 5 mm /3.2 x 10 kgm >
2 Mech. permissible speed n 15 000 min >
–1 12 000 min >
–1 Permissible axial motion of measured shaft –0.2/+0.4 mm with 0.5 mm scanning gap Vibration 55 to 2 000 Hz 100 m/s >
2 2 (EN 60 068-2-6) Shock 6 ms 1 000 m/s (EN 60 068-2-27) Max. operating temp. 115 °C Min. operating temp. –20 °C Protection EN 60 529IP 20 when mounted Weight (approx.) 0.13 kg >
1) * Please indicate when ordering >
2) Available in fi rst quarter of 2008. See the November 2006 edition of the Encoders for
Servo drives brochure for the previous version. Velocity-dependent deviations between the absolute and incremental signals >
47