Specifi cationsLB 382 up to ML 3040 mm Measuring standard Expansion coeffi cientStainless steel tape with AURODUR graduation Þ >
–6 –1 therm 10 x 10 K Accuracy grade ± 5 µm Measuring length ML* in mmSingle-section housing440 640 840 1040 1240 1440 1640 1840 2040 2240 2440 2640 2840 3040Reference marks * LB 382 LB 382 C Selectable with selector plates every 50 mm, standard setting: 1 reference mark in the centerDistance-coded Incremental signals » 1 V >
PP Grating periodSignal period40 µm40 µmCutoff frequency –3dB ‡ 250 kHz Traversing speed † 120 m/min Power supply without load5 V ± 5 %/< 150 mA
Electrical connection Separate adapter cable (1 m/3 m/6 m/9 m) connectable to mounting block Cable length >
1) † 150 m Required moving force † 15 N Vibration 55 to 2000 Hz † 300 m/s >
2 2 (IEC 60 068-2-6) Shock 11 ms † 300 m/s >
2 (IEC 60 068-2-27) Acceleration † 60 m/s in measuring direction Operating temperature 0 °C to 50 °C Protection IEC 60 529IP 53 when mounted according to the mounting instructionsIP 64 if
compressed air is connected via DA 300 Weight 1.3 kg + 3.6 kg/m measuring length >
1) * Please indicate when ordering With HEIDENHAIN cable >
33