LIF 4x1Output signals One TTL pulse for homing track H and limit switches L

Position detection

Signal level TTLU Besides the incremental graduation, the LIF 4x1 features a homing track and limit switches for limit position detection. The signals are transmitted in TTL levels over the separate lines H and L and are therefore directly available. Yet the cable has only a very thin diameter of 4.5 mm in order to keep the forces on movable machine elements to a minimum.
H ‡ 3.8 V at –I
H = 8 mAU
L † 0.45 V at I
L = 8 mA Permissible load R ‡ 680 −

I

I
L

I

† 8 mA Permissible cable length Max. 10 m
r = Reference mark position s = Beginning of measuring length (ML) LI = Limit mark, adjustable h = Switch for homing trackHo = Trigger point for homing Limit switchesHoming track LIF 400Recommended input circuitry of the subsequent electronicsDimensioning IC
3 e.g. 74AC14R
3 = 4.7 k −

43

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-52