Cable Glands ICG 653/UNIVERSAL Hazardous Area 88 Flameproof Exd & Increased Safety Exe & Restricted Dual Certified ATEX / IECEx 15.0mm Inspectable Compound Deluge Boot • Outdoor or indoor use. • For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’, elastomer and plastic insulated cables. • For particular use with:- Armour/Braid 'C' - Cables that are not effectively filled, compact and/or circular, Ø 'B' Ø 'E' Ø 'D' Entry Thread Metric Entry Application 'G' Approx (Fully Compressed Length) have tape bedding or have hygroscopic fillers. - Cables that exhibit ‘Cold Flow’ characteristics. - Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area. • See technical section for installation rules and regulations. CABLE GLAND SELECTION TABLE Entry Thread Size Size Metric Ref. Os O A B C C2 D E F M20 M20 M20 M25 M32 M40 M50 M63 M75 NPT * Standard or Option ½" ½" ¾" or ½" 1" or ¾" 1¼" or 1" 1½" or 1¼" 2" or 1½" 2½" or 2" 3" or 2½" Hexagon Dimensions Cable Acceptance Details Inner Sheath / Cores Armour / Braid ‘C’ Max. Over Max Inner Max. No. of Outer Sheath ‘B’ Cores ‘D’ Sheath ‘E’ Cores Min Max Orientation 1 Orientation 2 8.9 10.0 6 5.5 12.0 0.8 / 1.25 0.0 / 0.8 8.9 10.0 6 9.5 16.0 0.8 / 1.25 0.0 / 0.8 11.0 12.5 10 12.5 20.5 0.8 / 1.25 0.0 / 0.8 16.2 18.4 21 16.9 26.0 1.25 / 1.6 0.0 / 0.7 21.9 24.7 42 22.0 33.0 1.6 / 2.0 0.0 / 0.7 26.3 29.7 60 28.0 41.0 1.6 / 2.0 0.0 / 0.7 37.1 41.7 80 36.0 52.6 1.8 / 2.5 0.0 / 1.0 47.8 53.5 100 46.0 65.3 1.8 / 2.5 0.0 / 1.0 59.0 66.2 / 65.3¹ 120 57.0 78.0 1.8 / /2.5 0.0 / 1.0 'G' Across Flats Across Corners 24.0 24.0 30.0 36.0 46.0 55.0 65.0 80.0 95.0 26.5 26.5 32.5 39.5 50.5 60.6 70.8 88.0 104.0 67.0 67.0 67.0 73.6 78.0 82.4 88.7 92.7 99.4 All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread. ¹ Smaller value is applicable when selecting reduced NPT entry option. Note: Larger sizes are available. Technical Data • Flameproof Exd and Increased Safety Exe II 2 GD ExtD A21. • Certificate No’s: Baseefa06ATEX0058X and IECEx BAS 06.0015X. • Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. • Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1. • Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. • Deluge Protection to DTS01. • Operating Temperature Range: -60°C to +80°C. • Assembly Instruction Sheet: AI 301. • Alternative certification options available: Exe II BR-Exd IIC / Exe II Exd IIC / Exe II GOST R-Exe IIU GOST K- Approved for use in Kazakhstan DNV Marine Approval ABS Marine Approval Features • Provides a barrier seal to the individual insulated cores within the cable and prevents entry of the products of an explosion into the cable. • Assembly of the cable gland compresses and distributes the compound evenly to create a barrier seal at the point of entry into the enclosure. • The compound chamber may be separated from the cured compound • • • • • to ensure that the chamber has been effectively filled. If required, external voids can be repaired. Provides armour clamping, using one clamping arrangement for all armour / braid types. Provides an outer deluge seal to prevent moisture ingress to the cable armour / braid. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath. Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard. Alternative Reversible Armour Clamping Rings (RAC) Size Ref. B C C2 D E F SELECTION TABLE Steel Wire Armour / Braid / Tape Orientation 1 Orientation 2 0.9 - 1.25 0.5 - 0.9 1.2 - 1.6 0.6 - 1.2 1.2 - 1.6 0.6 - 1.2 1.45 - 1.8 1.0 - 1.45 1.45 - 1.8 1.0 - 1.45 1.45 - 1.8 1.0 - 1.45 Ordering Information Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information. Cable Gland Type ICG 653/UNIV Size C Thread M32 (OPTIONAL) AR Cable Gland Type ICG 653/UNIV Size C Thread 1 1⁄4"NPT (OPTIONAL) AR Two part sealing compound and assembly instructions are supplied with the cable gland. Connection Solutions www.ehawke.com HPG01 UPD 090610

Open the catalog to page 1

All Hawke International U.K catalogs and technical brochures

  1. 501/RCG

    2 Pages

  2. PL630

    1 Pages

  3. PL626

    1 Pages

  4. PL620

    1 Pages

  5. PL615

    1 Pages

  6. PL612

    1 Pages

  7. 321/R

    1 Pages

  8. 321

    1 Pages

  9. 114

    1 Pages

  10. 151/RAC

    1 Pages

  11. 150/RAC

    1 Pages

  12. 153/RAC

    1 Pages

  13. 123

    1 Pages

  14. 121

    1 Pages

  15. 701

    1 Pages

  16. 153/X

    1 Pages

  17. 755

    1 Pages

  18. 753

    1 Pages

  19. 711

    1 Pages

  20. 710

    1 Pages

  21. 653/T

    1 Pages

  22. 623

    1 Pages

  23. 453/T

    1 Pages

  24. 453/RAC

    1 Pages

  25. PSG 553/RAC

    1 Pages

  26. 501/453/UNIV

    1 Pages

  27. 501/453/RAC

    1 Pages

  28. HB Type

    1 Pages

  29. SK-Series

    4 Pages

  30. EJB Series

    1 Pages

Archived catalogs

  1. Cable Glands

    83 Pages