ICG 653/UNIV/L
1Pages

{{requestButtons}}

Catalog excerpts

ICG 653/UNIV/L - 1

Flameproof, Increased Safety, Dust Protection n Class - Zones - Divisions Certified ATEX / IECEx / c CSA us (for Lead Sheath Cables) Outdoor or indoor use. For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’, elastomer and plastic insulated cables with a lead inner sheath. For particular use with:- Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers. - Cables that exhibit ‘Cold Flow’ characteristics. - Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area. See technical section for installation rules and regulations. Group II Cable Glands CABLE GLAND SELECTION TABLE Entry Thread Size 'F' Size Ref. Cable Acceptance Details Inner Sheath / Cores NOTE 1 NOTE 2 Max Inner Max. No. Max. No. Sheath ‘E’ of Cores of Cores Hexagon Dimensions Across Across Flats Corners 'T' — All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread. Note 1: ATEX / IECEx certification only - Note 2: All other certification. Technical Data Ordering Information Flameproof Exd IIC Gb, Increased Safety Exe IIC Gb and Dust Extb IIIC Db II 2 GD. Certificate No’s: Baseefa06ATEX0058X and IECEx BAS 06.0015X. Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Deluge Protection to DTS01. Operating Temperature Range: -60°C to +80°C. Assembly Instruction Sheet: AI 301 and AI 336. Format for ordering is as follows: Alternative Seal (AR), add suffix AR to ordering information. Cable Gland Type Brass Brass Features Provides an inspectable, repairable barrier seal to the individual insulated cores within the cable, and prevents entry of the products of an explosion into the cable. Assembly of the cable gland compresses and distributes the compound evenly to create a barrier seal at the point of entry into the enclosure. Provides armour clamping, using one clamping arrangement for all armour / braid types. Provides a seal and an electrical bond on the cables lead inner sheath. Provides an outer deluge seal to prevent moisture ingress to the cable armour / braid. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath. Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard. Alternative Reversible Armour Clamping Rings (RAC) SELECTION TABLE Size Ref. B C C2 D E F Alternative certification options available: Two part sealing compound and assembly instructions are supplied with the cable gland.

Open the catalog to page 1

All Hawke International U.K catalogs and technical brochures

  1. 501/RCG

    2 Pages

  2. PL630

    1 Pages

  3. PL626

    1 Pages

  4. PL620

    1 Pages

  5. PL615

    1 Pages

  6. PL612

    1 Pages

  7. 321/R

    1 Pages

  8. 321

    1 Pages

  9. 114

    1 Pages

  10. 151/RAC

    1 Pages

  11. 150/RAC

    1 Pages

  12. 153/RAC

    1 Pages

  13. 123

    1 Pages

  14. 121

    1 Pages

  15. 701

    1 Pages

  16. 153/X

    1 Pages

  17. 755

    1 Pages

  18. 753

    1 Pages

  19. 711

    1 Pages

  20. 710

    1 Pages

  21. 653/T

    1 Pages

  22. 623

    1 Pages

  23. 453/T

    1 Pages

  24. 453/RAC

    1 Pages

  25. PSG 553/RAC

    1 Pages

  26. 501/453/UNIV

    1 Pages

  27. 501/453/RAC

    1 Pages

  28. HB Type

    1 Pages

  29. SK-Series

    4 Pages

  30. EJB Series

    1 Pages

Archived catalogs

  1. Cable Glands

    83 Pages