Enclosure Type Stainless Steel Size 6
Increased Safety EExe
Technical Data
• Increased Safety EExe. <ü> II 2 GD EExe II.
• SIZE 6 BASEEFA Certificate No. BAS0I ATEX 2106X.
• ZSIZE 6 BASEEFA Certificate No. BAS0I ATEX 2105U.
• Suitable for use in Zone I,Zone 2, Zone 21 & Zone 22.
• Construction and test standards
EN 50014, EN 50019 and EN 50281-1-1. IEC 60079-0 and IEC 60079-7.
• IP66 ingress protection to IEC 60529 and EN 60529.
• DTS0I deluge protection witnessed by EECS.
• Operating temperature range -40°C to +80°C.
• Temperature Class and Ambient T6 40°C. Optional T5 with ambients up to 65°C.
• Assembly instruction data sheet No. A.I. 266. For SIZE 6.
• Assembly instruction data sheet No. A.I. 267. For ZSIZE 6.
• Alternative Certification Options Available.
I I @ Exe II.
506 mm
08mm Padlocking Facility
210mm
450mm
Face A
4xMI0
, /Mounting •y Holes
Face D
Face B
\
MIO Integral Earth Stud
Face C
28mm
Captive Lid Gasket
-L _L —I
M6 Gland Plate Fixing Screws
Gland Plates on Faces B, C and D only.
404mm
Approx. weight : 27.5kg
CO
MAXIMUM QUANTITY OF ENTRIES PER FACE
Thread Size
MI6
M20/O
M20/A
M25
M32
M40
M50
M63
M75
Bottom Face C Quantity
44f
44#
30
21
14
9
6
4
3
Side Faces B & D Quantity
56?
56 f
36
26
16
1 1
7
5
4
AExe Il/Exe II.
US
# Serrated Washers/Locknuts with large outside diameters may foul on adjacent glands.
* Serrated Washers/Locknuts must not foul on aperture wall. Note: For Cable Entry Positions see page 34.
For full Technical Specification see page 35.
TERMINAL CAPACITY DATA
Terminal Type
Conductor Size (mm2)
Max. Volts
Max. Physical Terminal Content
Reduced Terminal Content at Max.Terminal Amps
Min.
Max.
Terminal Quantity
Amps
Terminal Quantity
Amps
WDU 2.5
0.5
2.5
550
380
4
14
21
WDU 4
0.5
4
750
320
5
13
28
WDU 6
0.5
6
550
240
8
12
36
WDU 10
1.5
10
550
200
1 1
10
50
WDU 16
1.5
16
550
160
16
9
66
WDU 35
2.5
35
750
120
27
7
109
WDU 70N
10
70
750
50
55
5
167
WDU 70/95
16
70
750
19
87
3
202
WDU 70/95
16
95
19
99
4
WDU 120/150
35
120
1100
16
117
4
234
WDU 120/150
150
16
125
4
WFF 35
2.5
35
1100
38
48
7
109
WFF 70
2.5
70
1100
16
101
5
167
WFF 120
6
120
1100
12
153
5
234
WFF 185
10
185
1100
9
212
4
307
WFF 300
25
300
1100
9
236
2
452
Notes: DFor Junction Box Wattage Factor & Combined Terminal Resistance see pages 37 - 39.
□ The box is supplied with an integral internal/external earth stud assembly.
□ WFF terminals are supplied fitted with cover.
All copyright reserved-Hitobell Ltd. This document and all copyricjt therein is the property of: Hawke International a cfusonof Hitobell Ltd (Amerrtoer of the Hubbell Group of Companies).
Copyright ConditionrThis document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner.
To the best of our knowledge the information contained in this leaflet, is accurate at the time of going to print and the company reserves the right to improve or modify any product illustrated without notification. The company is unable to accept liability for any inaccuracies, errors or omissions that may exist. It is the customer's responsibility to ensure that the product is suitable for their application.
H4WKE
I nternational
Smarter products www.ehawke.com
HWK05 Mar '02

pageCatalog pdf di En 2012-05-22-29