755
1Pages

{{requestButtons}}

Catalog excerpts

755 - 1

Cable Glands North American Cable Glands/Connectors Explosion Proof IECEx and ATEX Approved Flameproof Exd, Increased Safety Exe and Restricted Breathing ExnR (Note: Dual Marked UL & ATEX as standard). 'G' Approx (Fully Compressed Length) Nickel Plated Hub • Outdoor or indoor use. • For use with armoured jacketed cable, as permitted by the NEC. • See technical section for installation rules and regulations. CABLE GLAND SELECTION TABLE Entry Thread Size Size Ref. Hexagon Dimensions Cable Acceptance Details Inner Jacket / Cores Steel Wire Armour Across Across Flats Corners All dimensions in inches (except * where dimensions are in millimetres). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread. ¹ Smaller value is applicable when selecting standard NPT entry option. ² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner jacket diameter is 0.43 3 UL listing only applies to Steel Wire Armour. Technical Data • UL Listing No: E84940. • Suitable for use in: • Class 1, Division 2, Gas Groups A, B, C and D • Class 1, Zone 2, Gas Groups IIA, IIB and IIC • AExd IIC and AExe II Class 1, Zone 2. • Flameproof Exd, Increased Safety Exe II 2 GD and Restricted Breathing ExnR II 3G. • Certificate No’s: Sira 06ATEX1295X and IECEx SIR 06.0082X. • Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. • Construction and Test Standards: UL 2225, IEC/EN 60079-0, • • • • • IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0 and IEC/EN 61241-1. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Deluge Protection to DTS01. Operating Temperature Range: -50°C to +60°C (UL) and -60°C to +80°C (ATEX / IECEx). Assembly Instruction Sheet: AI 319 (UL) and AI 382 (ATEX / IECEx). Alternative certification options available: DNV Marine Approval GOST R-Exe IIU • Provides a barrier seal between the individual insulated conductors • • • • • within the cable and prevents entry of the products of an explosion into the cable. Assembly of the cable gland compresses and distributes the compound evenly to effect a barrier seal at the point of entry into the enclosure. Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured red to indicate Hazardous Location product. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket. Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard. Ordering Information Format for ordering is as follows: Cable Gland / Connector Type 755 Two part sealing compound and assembly instructions are supplied with the cable gland. Connection Solutions www.ehawke.com

Open the catalog to page 1

All Hawke International U.K catalogs and technical brochures

  1. 501/RCG

    2 Pages

  2. PL630

    1 Pages

  3. PL626

    1 Pages

  4. PL620

    1 Pages

  5. PL615

    1 Pages

  6. PL612

    1 Pages

  7. 321/R

    1 Pages

  8. 321

    1 Pages

  9. 114

    1 Pages

  10. 151/RAC

    1 Pages

  11. 150/RAC

    1 Pages

  12. 153/RAC

    1 Pages

  13. 123

    1 Pages

  14. 121

    1 Pages

  15. 701

    1 Pages

  16. 153/X

    1 Pages

  17. 753

    1 Pages

  18. 711

    1 Pages

  19. 710

    1 Pages

  20. 653/T

    1 Pages

  21. 623

    1 Pages

  22. 453/T

    1 Pages

  23. 453/RAC

    1 Pages

  24. PSG 553/RAC

    1 Pages

  25. 501/453/UNIV

    1 Pages

  26. 501/453/RAC

    1 Pages

  27. HB Type

    1 Pages

  28. SK-Series

    4 Pages

  29. EJB Series

    1 Pages

Archived catalogs

  1. Cable Glands

    83 Pages