You may also be interested in
Valve, Pressure limiter, Cylinder, High pressure pump, Hydraulic valve
Text version of the page
Check valves
Line rupture safety valves type LB
The line rupture safety valves type LB are check valves. They are
available as screw-in valves or with housing for in-line installation.
The line rupture safety valves are best installed directly on the actuator
(cylinder) which is to be safeguarded. This will prevent an uncontrollable,
accelerated movement (drop) of a loaded cylinder, when the hydraulic
back-pressure is lost as a result of a rupture of the pressurized line or
pipe connection.
When the flow through the valve increases above the pre-set limit, the
flow forces will exceed the opposing spring force and the valve will block
the flow immediately. The valve element in these valves is a shim.
There are two different versions
available. One valve design
completely blocks the flow when
actuated, whereas the other one
allows a minimum flow (via an
orifice) to slowly drop the load.
Nomenclature:
Design:
Adjustability:
pmax:
Qmax:
Line rupture safety valve
Valve insert
with housing for
in-line installation
Tool adjustable
700 bar
4 ... 160 lpm
2.5-18 2009
2
5
Simplified Detailed
Order examples
LB 4 C - 40
Line rupture safety valve size 4 as screw-in valve (coding C),
factory set for a response flow of 40 lpm
LB 2 G - 25
Line rupture safety valve size 2 with housing (coding G),
factory set for a response flow of 25 lpm
Standard
with add.
bypass
Basic types and general parameters
Flow
Qmax (lpm)
4 ... 25
4 ... 25
6.3 ... 50
6.3 ... 45
16 ... 80
25 ... 160
Pressure
pmax (bar)
500
700
500
700
500
500
Connection thread
(BSPP)
G 1/4 (A)
G 1/4 (A)
G 3/8 (A)
G 3/8 (A)
G 1/2 (A)
G 3/4 (A)
Basic type
and size
LB 1
LB 11 1)
LB 2
LB 21 1)
LB 3
LB 4
Symbol
Available orifice diameters 0.5 / 0.8 / 1.0 / 1.2 / 1.5 / 2.0
depending on type and size
Additional versions
• Line rupture safety valve with housing featuring a thread reduction
for special applications
• Versions with metric and UNF thread
1) The mounting thread is sealed additionally
|
|