Catalogue Directly controlled pressure limiting valves, differential pressure regulator type MV, SV etc.
www.hawe.de
print switch display
Page / 2
Make a request   
HAWE Hydraulik - 80637, 3017
/ 2
See other catalogues for HAWE Hydraulik
Text version of the page
Pressure valves
HYDRAULIK
Directly controlled pressure limiting and sequence valves type MV, SV etc.
Nomenclature:
Pressure limiting valve,
sequence valves
(directly controlled)
1
Design:
Individual valve for
pipe connection
Screw-in valve
Individual manifold
mounting valve
Assembly kit
Adjustability:
1
Tool adjustable
Manually adjustable
I
Pmax:
1
700 bar
Pressure valves gover the pressure within a hydraulic system. The types below are intended for the following purposes:
• Pressure limiting valve (safety valve):
Safeguarding the system against excessive pressure or for the limita­tion of working pressure.
• Sequence valves:
Generates a constant pressure difference between inlet and outlet of the flow.
Directly controlled valves feature a dampening device to ensure quiet operation, but they are also avail­able without it if necessary for an application. There is also a version of the pressure limiting valve (Type MV.X), conforming the Pressure Equipment Directive 97/23 EC, which features a type approval and a CE-stamping, usually neces­sary when used as safety valves for accumulators.
Qmax"
5 ... 160 Ipm
Basic types and general parameters Basic type MV 1) 5) MVS 1) 5) MVE 5)
MVG 3)
SV 1)
MVP 5) DMV 1)
MVCS 2) SVC 1) MVGC 3)
MVB 1)4)
2
1 I~t rZ~| rp^-P
j Ay. UJU
rn
Symbol
3
Function
Pressure
Pressure limiting valve and differential
Pressure limit-
Pressure limiting valve with
Pressure limiting
limiting
ing valve
free turn R — P via a by-
valve and differ-
valve
ential pressure
regulators
Brief
Corner
Corner Screw-in Straight-way Manifold
Twin valve as
Corner
Straight-way
Assembly kit 4)
description
valve for
valve for valve valve for mount-
shock valve for
valve for
valve for
pipe con-
pipe straight pipe ing valve
hydraulic
Pipe
straight pipe
nection
connec- installation tion
motors
connec­tion
installation
Pperm R (bar)
20
500
500
500
500
350
500
500
200
Size
13
14
4
5
6
8
Pressure range:
H: 700/5
N: 50/8
F: 80/20
F: 80/40
F: 80/75
E: 160/160
Pressure pmax (bar) /
M: 200/8
E: 160/20
E: 160/40
E: 160/75
C: 315/160
Flow Qmax (lpm)
H: 400/8
C: 315/20
C: 315/40
C: 315/75
B: 500/20
B: 500/40
B: 500/75
A: 700/12
A: 700/20
A: 700/40
Tapped ports (BSPP) 6)
G 1/4
G 1/4
G 1/4
G 3/8
G 1/2
G 3/4
G 3/8
G 1/2
G 3/4
G1
1) Only size 4, 5, 6, and 8
2) Only size 4, 5, and 6
3) Only size 13 and 14
4) For other types of assembly kits see also "Additional information"
5) Also version with type approval (TUV) available (size 4, 5, and 6)
6) Version for pipe connection
2.3-4
2005
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
pdf-page pdf di En 2008-10-42-16