| Specifications • Booster: Air driven, balanced opposed piston type, two stage. • High pressure Oxygen Chambers: Non-lube, hydrocarbon-tree, triple sealed and vented from the drive air chest. » High Pressure Tubing & Fittings: Stainless steel, 5,000 psi maximum oxygen working pressure • Air drive Section: No oiling required, corrosion resistant factory lubed at assembly, 150 psi max. drive pressure. > Particle Fitters: Inlet and outlet gas: 5 micron. Ail stainless steel. » Gauges: Stainless steel m.ubu. solid front 4-72s' dial size. • Port Sizes; Iniel and outlet gas: _" NPT female; Air Drive; ." NPT female, • Control Range Adjustment: Inlet m<nimum; 150 to 550 psi cutout Outlet maximum: 800 to 5,000 psi cutout Safety relief (outlet): BOO to 5,000 psi • Cooling: With air exhaust to both stages and intercooler, » Noise: 80 db range pulses, depending on working pressure {measured at 30 inches from booster). • Maintenance; Simple seal kit replacement. • Installation: No special foundation, no tie down required, and no electrical connections. |