| | | 5 CHANNELS TEMPERATURE INDICATOR | | |
| | | |
| | | | | | | | | | Model | TP3 | | | | Appearance | | | | | WxHxD(mm) | 96x48x100 | | | | Power supply | 100 - 240 V a.c( MO %), 50 - 60 Hz | | | | Power consumption | Max. 5 VA | | | | Input | Thermocouple : K, J, R | | | | RTD : DIN Pt 100 Q | | | | Display accuracy | Thermocouple : ±0.5 % of display value + 1 digit or ±3 "c RTD : ±0.5 % of display value +1 digit or ±2 "e | | | | Control operation | Indicator only (5 channels) | | | | Setting method | Digital method by setting key | | | | Function | .1 to 5 channel display by automatic or fixed 1 channel | | | | • Offset correction for each channel | | | | Ambient Temp. / Humidity | Max. 0 -c ~ 50 -c / 35 ~ 85 % R.H. | | | | | | | | | |
| | | |
| | | TEMPERATURE INDICATOR | | |
| | | |
| | | | | | | | | | | | Model | HN100 | | | | Appearance | | | | | | | WxHxD (mi) | 270 X166 x34 | | | | Use | Sauna facility, bathroom, fitness center, hospital, greenhouse, etc temperature display in spacious places | | | | FND size | 24 x 34 | | | | Case | Complete waterproof to IP57 | | | | Input type | Pt100(-100 ~ 400 "e, -19.9 ~ -99.9 -c) | | | | Input display accurity | Full span of ±0.5 % reg ±1 Digit | | | | Sensor appearance | Waterproof SUS TUBE | | | | Sensor cable length | 1.5 m | | | | Power cable length | 1.8 m | | | | Power Voltage | 12 V d.c | | | | | | | | | | | |
| | | |
| | | TEMPERATURE INDICATOR | | |
| | | |
| | | | | | | | | | | | Model | AT3 | AT6 | | | | Appearance | HESfil - ——_-±3Sj | m | | | | WXHXD(™) | 96 x48x100 | 72 x36 x95 | | | | Power voltage | 110/220 Va.c (50/60 Hz) | 100 -240 Va.c (50-60 Hz) | | | | Power consumption | 3 VA | | | | Input | R.T.D. , Thermocouple, Voltage/Current | | | | Permissible input resistance | T.C : 100 Q Mln. , R.T.D : 10 Q Min. | | | | Display accuracy | Max. 0.5 % of Max. range | | | | Display | Digital indicator | | | | Dielectric strength | 2,000 V a.c 50/60 Hz for 1 minute(Between + and - charging terminals) | | | | Vibration | Malfunction | 2 - 55 Hz, X Y Z each position for 10 minutes | | | | Durability | 10 - 55 Hz, 0.76 mm, X . Y . Z each position for 2 hours | | | | Shock | Malfunction | 100 % 6 positions , Each 3 time (Approx. 10 G) | | | | Durability | 300 % 6 positions , Each 3 time (Approx. 30 G) | | | | Ambient temperature and humidity | 0-50 *c -35-85 %R.H. (without condensation) | | | | 29 | | | | | | | | | | | |
| | | |
| | | | | | | | | | | | | | |