|
catalogue search
|
You may also be interested in
Sensor, Incremental encoder, Encoder, Humidity controller, Digital multimeter
Text version of the page
HYBRID RECORDERModelAppearanceFunctionPower voltagePower consumptionSampling CycleInputInput Display ResolutionAlarm Output W H D (143 143 226.66 channels multi input, zoom scale function, prescale function, 6 point relay output, 2 point event input, communication function (RS-485)100 - 240 V a.c , 47 - 65 Hz (Voltage Fluctuation Rate 10 %)Max. 50 VABelow max. 500 (Depend on the number of channel)Thermocouple (B, R, S, K, E, J, T), RTD (JPT100, PT100)d.c voltage input: 100 mV, 20 VDC current input: 0 - 24 connected with external resistor 250 Display up to 3rd decimal position 6 points relay contact outputT.C and mV input : Min. 2Input impedance, d.c volt : 400 kPermissible Wiring ResistanceApplied StandardAccuracyRelated to RecordRTD: Below 10 /1 wire (But the resistance of the 3 wires should be the same)Thermocouple / RTD (KS/IEC/DIN)Indicator: 0.25 % (Full Scale), Record: 0.5 % (Full Scale)Measuring point : 6 pointsResponse time : depend on the record speedRecord method : 6 dot dotting-methodRecord speed : 20 ~ 360 Availability of Record paper : on the front panel window, the lamp of P-END’ is ON and the record stops if there is no paperRecord paper : width 100 , length : 7.8 mTEMPERATURE & HUMIDITY CONTROLLERModelAppearance W H D ( )190 155 84190 155 84ProgramScreenFunctionMax. 100 pattern (Max. 6,000 segment)5.7 inch STN color LCD screen (Touch screen type)Pattern repetition : Max. 999 times, Partial repetition : Max. 255 times / Pattern link and editing100 - 240 V a.c, 50 - 60 Hz (Voltage variation rate :Power voltage10 %)Pt 100InputInput cycleMeasuring accuracyIndicating accuracyOutputor 4 - 20 d.c (0 - 5 V d.c)500 TemperatureHumidityS.S.R outputCurrent outputMin. 24 V d.c (Minimum pulse width : 0.2ms)4 - 20 100.0 ~ 200.0 4 - 20 d.c (0 - 5 V d.c) ( 100 ~ 200.0 Scale variable )0.0 ~ 100.0 Pt 100 (0.0 ~ 100.0 % R.H)(0.0 ~ 100.0 % R.H. 4 - 20 d.c (0 - 5 V d.c) Scale variable )Temperature : 0.1 % of F.S, Humidity : 1 % of F.S d.c Temperature : 1 point, Humidity : 1 point (PV, SV, MV selection)4 - 20Retransmission outputResistive Load Max. 600Contact inputON/OFF outputContact output typeDI : 8 pointsMax. 20 points (Relay : 12 points, Open collector : 8 points)Inner signal : 8 points, Alarm signal : 4 points each channel, Run/Stop signal : 1 point, 1st Ref. signal : 1 point, 2nd Ref. signal : 1 point Temp. / Humi. Up/Down, Soak signal : 6 points, Temp./Humi. Control signal : 2 points, Time signal : 8 points / 1 segment Error signal : 1 point, Sensor disconnection signal : 1 point, Wait signal : 1 point, Hold signal : 1 point, PT End signal : 1 point RS485-Max. communication distance 1.2Communication output, Max. 32 connections available, Communication speed : Max. 115,200 bpsRS 232 C, USB V 1.1 Internal FLASH memory, Temp./Humi. Each 86,400 pointsProgram information & Setting value back-up and recovery, Temp. / humi. Setting, Indicating value storage0 ~ 50Storage / CapacityStorage function Ambient Temp. / Humidity, 10 ~ 90 % R.H.(No condensation) Pt 10019 |