Portable Meters

Measurement Screen

Electrode condition and calibrationpoints shown.

pH Calibration

Detailed Calibration Check™ messages.

Measurement

Large backlit graphic display shows multiple messages along with the current measurement readings. SPECIFICATIONS HI 98180 HI 98181

Range pH: -2.0 to 16.0; -2.00 to 16.00; Temp: -20.0 to 120.0 °C (-4.0 to 248.0°F) pH: -2.0 to 16.0; -2.00 to 16.00; mV: ±2000; Temp: -20.0 to 120.0 °C (-4.0 to 248.0°F)

Language Selection

Resolution pH: 0.1; 0.01; Temp:0.1°C (0.1°F) pH: 0.1; 0.01; mV: 0.1; Temp:0.1°C (0.1°F)

Help screens and guides are avail- able in a choice of languages.

Accuracy pH: ±0.01; Temp: ±0.4°C (±0.8°F) (excluding probe error) pH: ±0.01; mV: ±0.2 mV; Temp: ±0.4°C (±0.8°F)(excluding probe error) pHCalibration Up to 2 point calibration, 7 standard buffers available(1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) Up to 3 point calibration, 7 standard buffers available(1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)

Help

SlopeCalibration From 80 to 110%

Users can consult the on-screen help from any mode simply by pressing the HELP key. The instrument will then explain the function and options currently available.

Temp. Compensation Manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F) Probes HI 1230B pH electrode w/BNC and HI 7662 temperature Logging Single reading PC Connectivity — Input Impedance 10
12 Ohms

GLP

Battery Type/Life (4) 1.2V AA rechargeable batteries/approx. 200 hrs continuous use (without backlight)

Comprehensive GLP functions are directly accessible by pressing the GLP key.

Recharger Inductive recharger (included) Auto-off User Selectable: 5, 10, 30, 60 min or can be disabled

ORDERINGINFORMATION

Environment 0 to 50°C (32 to 122°F); RH 95% Dimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”) Weight 525 g

Tank Tip

HI 98180 and HI 98181 are supplied with HI 1230B pHelectrode, HI 7662 temperature probe, pH 4.01 and pH7.01 buffer solutions; (4) 1.2V AA, 1300 mAh rechargeable batteries; HI 710042-01 inductive battery charger with power adapter; rugged carryingcase and instructions.

The pH requirements offresh water fish can vary greatly by species. Certain African cichlids which prefer hard water thrive at a pH of 8.0, while soft-water loving fish like discus need a pH of 6.5, and cold-water tropical fish like goldfish like pH 7.4 water best.Chemical test kits usingcolor charts have a reso- lution of only 0.5, while a

Rechargeable batteries with inductive recharger

These models have up to 200 hour extended battery life to guarantee long operationin the field. When the batteries are low, you don’t have to worry about carrying a spare set with you—the batteries can be recharged with
HANNA
’s inductive recharger.Simply leave the meter on the recharger for a few hours and you’re ready to go. The recharger can either be plugged in a standard 115V socket using the included
HANNA
adapter or a 12 VDC source such as a car's 12 volt accessory outlet.
HANNA

pH meter can berelied upon to provide incredibly precise and accurate readings of up to 0.01 pH!

(888) 815-6422 • aquaculture@hannainst.com www.hannainst.com 9