Portable Meters
HI9146 Dissolved Oxygen meter for FieldApplications
•Extended altitude compensation•Extended salinity compensation
•Designed for the field The extended altitude and salinity compensation makes this unit perfect for brine or high altitude systems. Automatic calibration and temperature
compensation with Hold button that freezes the reading on the LCD.
Available with 4 meter or 10 meter probe cables (see ordering information).
SPECIFICATIONS HI 9146
Range O >
2 : 0.00 to 45.00 mg/L; % Saturation O >
2 : 0.0 to 300.0%;Temperature: 0.0 to 50.0°C Resolution O >
2 : 0.01 mg/L; % Saturation O >
2 : 0.1% F.S.; Temperature: 0.1°C Accuracy >
(@20°C/68°F) O >
2 : ±1.5% F.S.; % Saturation O >
2 : 1.5% F.S.; Temperature: ±0.5°C Calibration Automatic, in air, at 100% Temp. Compensation Automatic, 0 to 50°C (32°F to 122°F) Altitude Compensation 0 to 4 km (0.1 km resolution) Salinity Compensation 0 to 80 g/L (1 g/L resolution) Probe HI 76407/4F polarographic, with 4 m (13') cable (included) Battery Type/Life (4)1.5V AA/approx. 200 hours of continuous use;auto-off after 4 hours of non-use; or input for 12 Vdc power adapter Environment 0 to 50°C (32 to 122°F); 100% max RH Dimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4'') Weight 500 g (1.1 lb.) >
ORDERING INFORMATION ACCESSORIES
HI 9146-04 and HI 9146-10 is supplied with HI 76407/4F probe with 4 m (13') cable(HI 9146-04) or HI 76407/10F probe with 10 m (33') cable (HI 9146-10) with protectivecap, 2 spare membranes, HI 7041S electrolyte solution (30 mL), batteries, hard carrying caseand instructions. HI 7041S Refilling electrolyte solution (30 mL) HI 76407A/P Replacement membrane (5 pcs) HI 710005 115 VAC/12 VDC power adapter (US plug) >
HI9145 Extended Range D.O. Meter
•Designed for harsh environments•Automatic calibration
•Automatic temperature compensation Ideal for fresh water systems where altitude and salinity compensation is unnecessary, thismodel is equipped with all the other features of the HI 9146 that makes it so popular.
SPECIFICATIONS HI 9145
Range O >
2 : 0.00 to 45.00 mg/L; % Saturation O >
2 : 0.0 to 300.0%;Temperature: 0.0 to 50.0°C Resolution O >
2 : 0.01 mg/L; % Saturation O >
2 : 0.1% F.S.; Temperature: 0.1°C Accuracy >
(@20°C/68°F) O >
2 : ±1.5% F.S.; % Saturation O >
2 : 1.5% F.S.; Temperature: ±0.5°C Calibration Automatic, in air, at 100% Temp. Compensation Automatic, 0 to 50°C (32°F to 122°F) >
ORDERING INFORMATION
Probe HI 76407/4 polarographic, with 4 m (13') cable (included) HI 9145 is supplied with D.O. probe HI 76407/4 with 4 m (13’)cable, 2 spare membranes, electrolyte solution HI 7041S (30
mL), batteries, rugged carrying case and instructions. Battery Type/Life (4)1.5V AA/approx. 200 hours of continuous use;auto-off after 4 hours of non-use; or input for 12 Vdc power adapter >
ACCESSORIES
Environment 0 to 50°C (32 to 122°F); 100% max RH HI 7041S Refilling electrolyte solution (30 mL) Dimensions/Weight 196 x 80 x 60 mm (7.7 x 3.1 x 2.4'')/500 g (1.1 lb.) HI 76407A/P Replacement membrane (5 pcs) >
(888) 815-6422 • aquaculture@hannainst.com
www.hannainst.com 23