Portable Meters

Aquaculture Catalog - 9073 HI 991300 • HI991301 pH/EC/TDS/Temperature with 1 Probe

Perfect for freshwater applications; this meter allows the user to measure four vital parameterswithout having to change probes or recalibrate!

No switchingmetersin the field!
SPECIFICATIONS HI 991300 HI 991301
pH: 0.00 to 14.00; EC: 0 to 3999 µS/cm;TDS: 0 to 2000 ppm (mg/L); Temp.: 0.0 to60.0°C or 32.0 to 140.0°F pH: 0.00 to 14.00; EC: 0.00 to 20.00mS/cm; TDS: 0.00 to 10.00 ppt (g/L);Temp.: 0.0 to 60.0°C or 32.0 to 140.0°F Range Resolution pH: 0.01; EC: 1 µS/cm; TDS: 1 ppm;Temperature: 0.1°C or 0.1°F pH: 0.01; EC: 0.01 mS/cm; TDS: 0.01ppt; Temperature: 0.1°C or 0.1°F Accuracy
(@20°C/68°F) pH: ±0.01; EC/TDS: ±2% F.S.; Temperature: ±0.5°C or ±1.0°F pH Calibration Automatic at 1 or 2 points with 2 sets of memorized standard buffers (pH4.01/7.01/10.01 or pH Automatic, 1 point at 1382 ppm (CONV0.5) or at 1500 ppm (CONV 0.7) or at1413 µS/cm (others) Automatic, 1 point at 6.44 ppt (CONV 0.5)or at 9.02 ppt (CONV 0.7) or at 12880µS/cm (others) EC/TDS Calibration TDS Conv. Factor Selectable 0.45 to 1.00 with 0.01 increments (default 0.50) Temp. Compensation pH: automatic; EC/TDS: automatic, BETA ( β ) is adjustablefrom 0.0 to 2.4%/°C w/0.1 increments Probe HI 1288 pH/EC/TDS/Temp., DIN connector, 1 m (3.3’) cable (included) Battery Type/Life (4) 1.5V AAA/approx. 100 hrs of continuous use Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions/Weight 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)/210g (7.4 oz.)
ORDERING INFORMATION
HI 991300 and HI 991301 is supplied with HI 1288 pH/EC/TDS/T probe, with 1 m (3.3’) cable, batteries, rugged carrying case and instructions.
ACCESSORIES
HI 1288 pH/EC/TDS/Temperature probe HI 70030P 12880 µS calibration sol. (25 x 20 ml) HI 77100P 1413 µS/pH 7 calibration solution (10 x 20 mL each) HI 77300P 1382 ppm/pH 7 calibrationsolution (10 x 20 mL each) HI 710007 Shockproof rubber boot, blue HI 710008 Shockproof rubber boot, orange HI 70038P 6.44 ppt calibration solution (25 x 20 ml) HI 77200P 1500 ppm/pH 7 calibration solution (10 x 20 mL each) HI 77400P pH 4; pH 7 calibration solution (5 x 20 mL each)

HI 146-01 °F Digital Thermometer

Spot Checkor MonitorLightweightPortability

•Cal-Check

®

feature•Stainless steel probe •Allows for continuous monitoring•°C model available A precision thermometer with stainless steel probe and Cal-Check

®

. Use the optional probeholder (HI 750146) to mount the probe where it’s entirely hidden from main view but still easy to check the temperature of your tank (do not immerse the probe handle). More accurate than mostconventional aquarium thermometers, this meter will run without interruption for five years on a single AA battery.

SPECIFICATIONS HI 146-01
Range -58.0 to 302.0°F Resolution 0.1°F (-58.0 to 199.9 °F),1°F (200 to 302 °F) Accuracy ±0.5°F (4 to 194°C), ±1°F (outside) Probe (fixed) stainless steel, 160 x dia 3 mm (6.3 x dia 0.1’’), 2 m (6.6’) cable Battery type/life (1)1.5V AA / approx. 5 years Environment 32 to 122°F; RH max 95% 0 to 50°C; RH max 95% 0 to 50°C; RH max 100% Dimensions 86 x 110 x 43 mm (3.4 x 4.3 x 1.7’’) Weight 150 g (5.3 oz)
ORDERING INFORMATION ACCESSORIES
HI 146-01 is supplied with probe, battery and instructions HI 750146 Wall-mounted probe holder