Portable Meters
SPECIFICATIONS HI 9828
Range 0.00 to 14.00 pH pH Resolution 0.01 pH Accuracy ±0.02 pH Range ±600.0 mV mV of pH input Resolution 0.1 mV Accuracy ±0.5 mV Range ±2000.0 mV ORP Resolution 0.1 mV Accuracy ±1.0 mV Range 0.0 to 500.0% / 0.00 to 50.00 mg/L Resolution 0.1% / 0.01 mg/L Dissolved Oxygen Accuracy 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 mg/L: ±1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ±3% of reading Range 0.000 to 200.000 mS/cm (actual EC up to 400 mS/cm) Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cmAutomatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm ; 0.1 mS/cm from 100.0 to 400.0 mS/cmAutomatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm Conductivity Resolution Accuracy ±1% of reading or ±1 µS/cm whichever is greater Range 0 to 999999 W•cm; 0 to 1000.0 kW•cm; 0 to 1.0000 MW•cm Resistivity Resolution Dependent on resistivity reading Range 0 to 400000 mg/L or ppm (the maximum value depends on the TDSfactor) Manual:1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt)Auto-range scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)Auto-range g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt) TDS Resolution Accuracy ±1% of reading or ±1 mg/L Range 0.00 to 70.00
PSU (extended Practical Salinity Scale) Salinity Resolution 0.01 PSU Accuracy ±2% of reading or 0.01 PSU whichever is greater Range 0.0 to 50.0 σ t, σ 0, σ 15 Seawater Specific
Gravity Resolution 0.1 σ t, σ 0, σ 15 Accuracy ±1 σ t, σ 0, σ 15 Range 450 to 850 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa Atm. Pressure Resolution 0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa Accuracy ±3 mmHg within ±15°C from the temperature during calibration Range -5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K Temperature Resolution 0.01°C; 0.01°F; 0.01K Accuracy ±0.15°C; ±0.27°F; ±0.15K pH Automatic 1, 2, or 3 points with 5 memorized standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer ORP Automatic at 1 custom point Conductivity,Salinity Automatic 1 point with 6 memorized standards (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point Calibration D.O. Automatic 1 or 2 points at 0, 100% or 1 custom point Resistivity, TDS, σ Based on conductivity or salinity calibration Atmos. Pressure Automatic at 1 custom point Temperature Automatic at 1 custom point Temperature Compensation Automatic from -5 to 55°C (23 to 131°F) Logging Memory Up to 60000 samples with 13 measurements each Logging Interval 1 second to 3 hours Computer Interface USB (with HI92000 software) Waterproof Protection Meter IP67, Probe IP68 Environment 0 to 50°C (32 to 122°F); RH 100% Power Supply (4) 1.5V alkaline C cells (approx. 150 hours of continuous use without backlight)/(4) 1.2V rechargeable C cells (approx. 70 hours of continuous use without backlight) Dimensions Meter: 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”); Probe: 270 x 46 mm DIA (10.6 x 1.8” DIA) Weight Meter: 750g (26.5 oz.); Probe: 750g (26.5 oz.) >
ORDERINGINFORMATION
HI 9828 is supplied with HI 769828 pH/ORP/DO/EC/
Temperature probe; HI 9828-25 quick calibration standard solution, 500 mL; probe maintenance kit; 4 rechargeable C size, Ni-MH batteries; power adapter & cable; car 12V accessory outlet adapter; (5) iButton >
© s with holder; calibration vessel, HI 7698281 USB interface cable; HI 92000 Windows >
® compatible software and instruction manual in a rugged carrying case. >