Portable Meters
HI 9026 pH/ORP Meter with Calibration Check™
•Backlit, dual-level LCD•Measures in °C or °F
•7 memorized buffers for calibration
•Custom calibration with two custom buffers•Display hold and memory storage•User-selectable calibration reminder This advanced pH/ORP meter has a large, backlit LCD for clear readings in dark environments.
SPECIFICATIONS HI 9026
Range pH: -2.00 to 16.00; mV: ±699.9 to ±1999; Temp.: -20.0 to 120.0°C/-4.0 to 2482.0°F Resolution pH: 0.01; mV: 0.1, 1; Temperature: 0.1°C/0.1°F Accuracy >
(@20°C/68°F) pH: ±0.01; mV ±0.2, ±1; Temperature: ±0.4°C/±0.8°F Calibration Check™ Check of the electrode status during calibration pH Calibration Automatic, 1 or 2 point with 7 memorized buffer values (pH 1.68, 4.01, 6.86, 7.01,9.18, 10.01, 12.45); + 2 custom buffers Temp Comp Automatic or manual, -20 to 120°C (-4°F to 248°F) pHElectrode HI 1230B, double junction, PEI body, gel filled, BNC conn. and 1 m cable (included)
Temperature probe HI 7669 with 1 m (3.3’) cable (included) Input Impedance 10 >
12 Ohm Battery Type/Life (4) 1.5V AA / approx. 500 hours of continuous use (without backlight);auto-off after 20 minutes of non-use (can be disabled) Environment 0 to 50°C (32 to 122°F); 100% RH Dimensions 196 x 80 x 60 mm (7.7 x 3.1 x 2.4’’) Weight 500 g (1.1 lb.) >
ORDERING INFORMATION
HI 9026 is supplied with HI 1230B
ph electrode, HI 7662 temperature probe, pH 4 and pH 7 buffer sachets,100 mL plastic beaker, batteries, rugged carrying case and instructions. >
ACCESSORIES
HI 3230B ORP electrode, gel filled, PEI body, BNCconnector, 1 m cable HI 7010L pH 10.01 buffer solution, 500 mL HI 70300L Electrode storage solution, 500 mL >
Tank
Tip
HI 7007L pH 7.01 buffer solution, 500 mL HI 7061L Electrode cleaning solution, 500 mL >
ORP is the best way to measurewater’s potential ability to oxi-
dize organic contaminants. In
other words, ORP can be used
as an indicator of water quality.
Many consider an ORP level of
250-400 mV to be reflective of
good to optimal water quality;
this level can be maintained by
using aeration, ozone, or a UV
sterilizer. ORP levels below 200
mV can indicate low dissolved
oxygen, high nitrites, or high
DOC (Dissolved Organic
Carbon). DOC promotes the
increase of harmful bacteria.
However, ORP levels exceeding
550 mV are harmful to animals
and plants. Levels this high
should only be used as a steril-
izing agent to treat water that
contains no live stock.
HI9026Calibration Check™ System
Clean Electrode Expired Calibration
Each time pH calibration is
performed, the meter inter-
nally compares the new
calibration with the one
previously stored. When this comparison indicates a significant difference, the clean message blinks on the LCD to advise the user
that the pH electrode may need to be cleaned
and another calibration will need to be performed. The instrument is providedwith a real time clock (RTC)
in order to monitor the time
elapsed since the last pH
calibration. The RTC is reset every time the meter
detects a calibration time-out. The CAL tag will
start blinking to warn the user that the meter should
be calibrated.
Electrode Condition
The HI 9026 display features a bar graph which displays the status of the electrode after calibration. The bargraph remains active for 12 hours after calibration, then only the frame is shown on the display.
61 to 80% Life41 to 60% Life21 to 40% Life1 to 20% Life0% Life81 to 100% Life