You may also be interested in
Relay, Float level sensor, Reed sensor, Proximity switch, Level sensor
Text version of the page
HA15-2
BENEFITS
Hermetically sealed switch
Contacts have no effect on their external environment
Low space requirement
Zero operating power required
Fit and forget durability
APPLICATIONS
Reed Relays
Security
Limit Switching
Telecoms line switching
Office equipment
Light inductive loads
European mains Voltage Switching
Notes
1)
For details on electrical specifications contact Hamlin
2)
Contact rating-Product of the switching voltage and current should never exceed the wattage rating. Contact Hamlin for additional load/life information
3)
Operate (inc. bounce / Release Time-per Eia/NARM RS421A, diode suppressed coil.
4)
Pull in Range-Contact Hamlin for tolerances within this range.
5)
Rating Sensitivity, The value at which contact ratings and operating characteristics are determined. Deratingmay be required for lower values
6)
Storage Temperature-Long time exposure at elevated temperature may degrade solderabilityof the leads.
Hamlin USA Tel: +1 920 648 3000 Fax: +1 920 648 3001 Email: sales.us@hamlin.com Hamlin UK Tel: +44 (0) 1379 649700 Fax: +44 (0) 1379 649702 Email: sales.uk@hamlin.com Hamlin Germany Tel: +49 (0) 6142 923920 Fax: +49 (0) 6142 923921 Email: sales.de@hamlin.com Hamectrol France Tel: +33 (0) 1 6047 3000 Fax: +33 (0) 1 6015 9136 Email: sales.fr@hamlin.com Hamlin China Tel: +86 512 69365 800 Fax: +86 512 69365 817 Email: sales.cn@hamlin.com DETAILS ON THIS DATA SHEET ARE PROVIDED FOR INFORMATION PURPOSES ONLY &SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSEProduct performance may be affected by the application that the part is used for.Upon request Hamlin will assist purchasers by providing information specific to a particular application.Hamlin disclaims all liability whatsoever for any purchasers reliance upon the informationcontained in this data sheet without further consultation with Hamlins authorised representatives.
Dimensions: (inch)
mm
Switch type
HA15]2
Contact Form
A (SPST)
ELECTRICAL RATINGS
Sensitivity (5)
17]23
22+
Contact Rating (2)
Watts ]max
20 W for 100]265 VAC loads10 W for all other loads
Voltage
Switching
VAC rms max / VDC
265 / 200
265 / 200
Breakdown
VDC ]min
400
450
Current
Switching
A ]max (AC/DC)
0.3 / 0.4
0.35 / 0.5
Carry
A ]max (DC)
1.4
1.5
Resistance
Contact, Initial
]max
0.100
0.100
Insulation
]min
10
10
Capacitance
Contact
pF ]typ
0.2
0.2
Temperature
Operating
C
]20 to +125
]20 to +125
Storage (6)
C
]65 to +125
]65 to +125
OPERATING CHARACTERISTICS
Operate time (3)
ms ]max
0.6
Release Time (3)
ms ]max
0.2
Shock
11ms 1/2 sine wave
G ]max
100
Vibration
50]2000 Hertz
G ]max
30
Resonant Frequency
Hz ]typ
4000
MAGNETIC CHARACTERISTICS
Pull]in Range (4)
Ampere Turns
17]23, 22]28, 27]33
Test Coil
L4989
|
|