59050 PCB Mount Features and Benefits
File E61760(N)
Actuator
Sensor
Features
• 2 part magnetically operated proximity sensor
• Standard normally open and high voltage normally open contact configuration
• Moulded stand-offs to allow board washing
• Customer defined sensitivity
Benefits
• Mounts directly into printed circuit board
• No standby power requirement
• Operates through non-ferrous materials such as wood, plastic or aluminium
• Hermetically sealed, magnetically operated contacts continue to operate long after optical and other technologies fail due to contamination
• Simple installation and adjustment
Applications
• Position and limit sensing
• Security system switch
• Door switch
DIMENSIONS (in) mm
A
Max
B
Max
C
+ .10 (0,25)
D
Max
E
+ .015 (0,38)
57050
(.265) 6,73
(.900) 22,86
See Note Below
(.180) 4,57
59050
(.265) 6,73
(.900) 22,86
(.800) 20,32
(.170) 4,32
3 3,30
Mounting:(.062) 1,57 thick board, (.125) 3,17 holes 13,72 on (.720) 18,28 nom.centres.
CUSTOMER OPTIONS - Switching Specifications
TABLE
Normally Open
Normally Open High Voltage
Contact Type
Switch Type
1
2
Power
Watt - max.
10
I0
Voltage
Switching
Vdc - max.
200
300
Breakdown
Vdc - min.
250
450
Current
Switching
A - max.
0.5
0.5
Carry
A - max.
1.2
I.5
Resistance
Contact, Initial
Q - max.
0.2
0.2
Insulation
Q - min.
I010
I010
Capacitance
Contact
pF - typ.
0.3
0.2
Temperature
Operating
°C
-40 to +105
-20 to +I05
Storage
°C
-65 to +105
-65 to +I05
Time
Operate
ms - max.
1.0
I.0
Release
ms - max.
1.0
I.0
Shock
11ms 1/2 sine
G - max.
100
I00
Vibration
50-2000 Hz
G - max.
30
30
CUSTOMER OPTIONS - Sensitivity,Cable Length and Termination Specification
Sensitivity Options:-
Activate Distances are approximate using Hamlin 57050 actuator as illustrated
Switch AT before modification
Select Option
S
T
U
V
Switch Type
Pull In AT Range
Activate Distance d
(in) mm
Pull In
AT
Range
Activate Distance
d
(in) mm
Pull In
AT
Range
Activate Distance
d
(in) mm
Pull In
AT
Range
Activate Distance
d
(in) mm
1
2
Normally Open
12-18
(.295) 7,5
17-23
(.236)
6,0
22-28
(.197)
5,0
27-33
(.177)
4,5
High Voltage
ORDERING INFORMATION
N.B. 57050 actuator sold separately
I 59050
X
X
00
0
Series 59050 Switch Type Sensitivity
Table 1 Table 2
Hamlin USA Hamlin UK Hamlin Germany Hamectrol France
ISSUE No:4 DATE: 1/5/3
Tel: +1 920 648 3000 • Fax: + 1 920 648 3001 • Email: sales.us@hamlin.com
Tel: +44 (0)1379 649700 • Fax:+44 (0)1379 649702 • Email: sales.uk@hamlin.com
Tel: +49 (0) 6181 953660 • Fax: +49 (0) 6181 9536666 • Email: sales.de@hamlin.com
Tel: +33 (0) 1 4687 0202 • Fax: +33 (0) 1 4686 6786 • Email: sales.fr@hamlin.com
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE. Product performance may be affected by the application to which the product is put. Upon request, HAMLIN will assist purchasers by providing information specific to any particular application. HAMLIN disclaims any and all liability whatsoever for any purchaser's reliance upon the information contained on this data sheet without further consultation with authorised representatives of HAMLIN.
25

pageCatalog pdf di En 2012-02-07-14