BARE MCP BARE MCP
DIMENSIONS AND SPECIFICATIONS DIMENSIONS AND SPECIFICATIONS
Circular MCP (Bare MCP)
OUTPUT SIDEINPUT SIDE INDICATOR 1 θ ABC D TMCPA0056EA
MCPF0006 F1551-01 F6584-01 F1552-01-09F1094-01-09 F1208-01 F1217-01 F1942-04 F2395-04 Unit ParameterType Outer Size AElectrode Area BEffective Area CThickness D
Channel DiameterChannel PitchBias Angle 17.9 17 14.50.4812
158 24.8 23.9 200.4110
125 32.8 31.8 278, 1260Inconel10 38.4 36.5 32
20 to 200 49.9 49 42
10 to 200 86.7 84.7 77
10 to 100 113.9 112 105
5 to 50 mmmmmm
mm µ m 0.48121588 µ m θ Open Area RatioElectrode MaterialGain (Min.) degrees %—
—M Ω >
5 4 Resistance >
5 100 to 700 50 to 500 30 to 3000.57 % of Strip Current Dark Current (Max.) >
5 pA·cm >
-2 Maximum Linear Output >
5 4 —kV Supply Voltage >
6 1.0-50 to +70
1.0025310.4812150.4812150.4110120.48121582 to 30 Operating Ambient Temperature >
6
2322 ° C >
NOTE: 1 This mark indicates the MCP input side. 2 Variant types with 6 µ m channel diameter are also available. 3 Wide dynamic range type designed to obtain high output current. (See the graph "MCP Saturation Characteristics" in the page 2.) 4 The strip current is the current which flows along the channel wall when a voltage is applied between MCP IN and OUT. This is found by dividing the applied voltage by the MCP plate resistance. 5 Supply voltage: 1.0 kV, vacuum: 1.3 × 10 -4 Pa, operating ambient temperature: +25 ° C 6 Vacuum: 1.3 × 10 -4 Pa 3 >