You may also be interested in
Relief valve, Hose, Check valve, 2-way valve, Connector
Text version of the page
88
COMPRESSION TUBE FITTINGS
Dimensions are for reference only, and are subject to change without notice.
INSTALLATION
INSTRUCTIONS FOR
LET-LOK® FITTINGS
38mm-50mm
11/4’’-2’’
1. Close the nut and ferrules
on the tube with a hydraulic tool.
2. Open and release from the tool.
3. Apply the G-Rapid paste on areas A and B.
4. Tighten the nut on body 1/2 a turn with a wrench
To order:
use part No. 3900753
A
B
ACCESSORIES
ADDITIONAL SIZES:
GOLDEN GAUGE
PART NO. MIN. NOMINAL WALL THICKNESS
3901508 Golden Gauge 1/16”
3901509 Golden Gauge 1/8”-2-3 mm
3901510 Golden Gauge 3/16”- 4 mm
3901513 Golden Gauge 5/16”- 8 mm
3901511 Golden Gauge 10 mm
3901247 Golden Gauge 5/8”-14-15-16 mm
3901246 Golden Gauge 3/4”-18 mm
3901512 Golden Gauge 7/8”-20-22 mm
3901245 Golden Gauge 1”-25 mm
GAUGE
PART NO. MIN. NOMINAL WALL THICKNESS
3900098 1/4” (6mm), 3/8”, 1/2” (12mm)
SIZE:
GOLDEN GAUGE
G-RAPID PLUS LOW FRICTION PASTE
HIGH SAFETY
In applications where severe
conditions and high pressure exist,
we recommend the following installation procedures:
1. Check that the nut is finger tight.
2. Insert the tube (up to the shoulder).
3. Rotate the nut with a wrench until the tube does not rotate freely.
4. Mark position of the nut.
5. Rotate the nut 1-1/4 turns.
This method ensures that even if the tube O.D. is at the minimum tolerance,
the ferrules will be in contact with the tube for the full 1-1/4 rotation.
|
|