Process (1)
16Pages

{{requestButtons}}

Catalog excerpts

Process (1) - 2

Process Instruments Drinking Water Օ Wastewater Pure Water/PowerՕ Industrial Water Food and Beverage Case NEMA-4X(indoor)/IEC 529 (IP66) with provision for air purge. Reagent enclosure is drip-proof > Range 1 to 500 mg/L as CaCO Drain > 3 totalalkalinity; 5 to 250 mg/L as CaCO Gravity, air break or ventrecommended > 3 phenolphthalein alkalinity > Accuracy Sample Flow Rate Better than 5% of reading or ѱ1.0 mg/L, whichever is greater 100-2000 mL/min maximum > Sample Filter Inlet > Repeatability 1/4" OD NPT male or female > Better than 3% of reading or α0.6 mg/L, whichever is greater Sample...

Open the catalog to page 2
Process (1) - 3

Process Instruments Outstanding accuracy, quick response, and reliable performancemake the APA 6000 the ideal choice for applications requiring precise control of treatment processes. Featuring a compact, space-saving design, the analyzer automatically primes, cleans, and calibrates critical components without operator intervention. Easy to install and easy to maintain, these rugged analyzers include a controlled reagent dispersion system that decreases sample size, reduces reagent consumption, and minimizes waste disposal. Each analyzer includes an installation kit, one monthՒs supply...

Open the catalog to page 3
Process (1) - 4

Process Instruments ҕ Drinking Water Outputs Two 4-20 mA outputs included; total of up to 14 programmable 4-20 mA outputs (with optional Signal Output Modules) > Speciation Network Connectivity Free and Total Ammonia (NH AquaTrend network using the LonWorks protocol > 3 ) andMonochloramine (NH Compliance/Certification > 2 Cl) as N. Also menu selectable to display as Cl UL, CSA and IEC safety standards,FCC & European RFI standards and European EMI standards > 2 Approximately 522 x 627 x 527 mm (21" tall, 25" wide, 21" deep) Enclosure Range > NEMA 4X (indoor)/IEC529 (IP66) withprovision for...

Open the catalog to page 4
Process (1) - 5

Process Instruments The Hach AMTAX sc Ammonia Analyzermeasures NH 4 -N concentrations as low as0.05 mg/L and as high as 1000 mg/L. With a fast, 5-minute response time, itenhances control of the nutrient removalprocess. This is no black boxӔ systemyou get transparent, high-qualitymeasurements for reliable values. AMTAX scAMMONIA ANALYZER WITH Filterprobe sc Primary Applications Pr od. No. Description Price 6157200AMTAX sc Ammonia Analyzer$15,235.00 > ו Wastewater Industrial Water 6157300AMTAX sc Ammonia Analyzer15,889.00 0.05 to 20 mg/L, 115 Vac; includes filtration probe with 5 m heated...

Open the catalog to page 5
Process (1) - 6

Process Instruments Exclusively from Hach,CARTRICALՙ technologycalibrates each electrodeindividually and calibrates all three electrodes to each other. This results in reducedinterferences and improvedaccuracy. > Municipal Wastewater Calibration > Sensor cartridge, calibrated (sensorcode contains factory calibration in code form). Entry of sensor codecalibrates the sensor. No standardsolutions needed > Ion-selective electrodes forammonium and potassium with pHD reference electrode andtemperature sensor > Optional: 1- or 2-point inline matrixcorrection adapts sensor to thewastewater matrix >...

Open the catalog to page 6
Process (1) - 7

Process Instruments The Hach CL17 samples every 2.5 minutes, using less than 475 mLeach of indicator and buffer over a 30-day period. A linear peristaltic pump, seal-free mixer, easy-to-clean cell, and compact colorimeter combine to ensure reliable, low-maintenance operation. > The CL17 provides a programmable 4-20 mA recorder output and two user-selectable alarms with SPDT relays that signal out-of-limit test results or system problems. > The state-of-the-art mixing system in Hachs CL17 operates with nomoving parts. A self-cleaning stir bar in the sample chamber instantly generates a...

Open the catalog to page 7
Process (1) - 8

Process Instruments Optional acidification (forcleaning) and intermittent flowaccessories link in series sothey only take up one sensorport in the controller. Pr od. No. Description Price COMPLETEANALYZERS > Note: sc100 shown with optional mounting panel. 60432009184 sc TFC Chlorine Sensor$4,028.00 Preassembled panel including HOCl > + OCl > - probe with integral temperature and pH probe and flow control, sc100 controller, and mounting panel for sc100 Primary Applications > Drinking Water Օ Wastewater Pure Water/PowerՕ Industrial Water SENSORONLY LXV432.99.00001 9184 sc TFC Chlorine Sensor...

Open the catalog to page 8
Process (1) - 9

Process Instruments Optional acidification (forcleaning) and intermittent flowaccessories link in series sothey only take up one sensorport in the controller. Pr od. No. Description Price COMPLETEANALYZERS 60434009187 sc Chlorine Dioxide Sensor$3,447.00 6043401 Preassembled panel including ClO Same as 6043400 but with > 2 3,595.00 probe with integral temperature and flow control, sc100 controller, and mounting panel for sc100 MODBUS > Note: sc100 shown with optional mounting panel. RS485 output 6043002 Same as 6043400 but with 3,606.00 MODBUS > ή RS232 output SENSORONLY Primary Applications...

Open the catalog to page 9
Process (1) - 10

Process Instruments Enhanced performance designs for Ultra-pure Water, Sanitary (CIP),Boiler/Condensate and General Purpose applications. > Pure Water/PowerՕ Industrial Water Temperature Range > Cell Constants and Measuring Ranges Sensor Cell ConstantAbsolute Range (S/cm) Practical Range (յS/cm)Resistivity (Mohm) 0.05 0100 0֖1000.00220 0.5 0֖1,000 11,000 0.001-20 10֖2,000 102,000 not applicable 5 0֖20,000 5020,000 not applicable 10 0֖200,000 200200,000 not applicable Accuracy Response Time ֱ2% of reading above 200 S/cm 90% of reading within 30 seconds of step change Pressure Range...

Open the catalog to page 10
Process (1) - 14

Process Instruments Alarms Two SPDT alarm relays included;total of up to 14 programmablealarm relays (with optional Signal Output Modules) Ranges > Low-range: 0.05 to 2.0 mg/L as Cu > 2+ High-range: 1.0 to 10.0 mg/L as Cu Low-range: ұ5% or 0.03 mg/L,whichever is greaterHigh-range: ѱ5% or 0.05 mg/L,whichever is greater > 2+ Accuracy Outputs Two 4-20 mA outputs included; totalof up to 14 programmable 4-20 mAoutputs (with optional Signal Output and Power Supply Modules) > Resolution Network Connectivity > Ѯ 0.01 ppm AquaTrend network, using theLonworks > ٮ 3% of reading or ѱ0.03 mg/L,whichever...

Open the catalog to page 14

All Hach catalogs and technical brochures

  1. Flow

    22 Pages

  2. Process (4)

    14 Pages

  3. Process (3)

    18 Pages

  4. Process (2)

    24 Pages

  5. Controllers

    12 Pages

  6. Parameters (3)

    26 Pages

  7. Parameters (2)

    24 Pages

  8. Parameters (1)

    28 Pages

  9. Sample Cells

    8 Pages