Controllers - 11 / 12 Pages

Model 33 Controller pH/ORP, Conductivity, Dissolved Oxygen, Flow

Controllers

Backlit LCD With Multiple Language CapabilitiesՕ Menu-Guided Operation
Simple Interactive Diagnostics
Օ Password-Protected Access
Panel Mounted, Polycarbonate 1/4 DIN Enclosure (NEMA 4X When Panel Mounted)Օ (2) 0/4-20 mA Outputs and (2) Relays

The Model 33 Controllers are best suited for panel mountedinstallations where high level control, 0/4-20 mA outputs, and relay
output options are desired. The Model 33 is a 1/4 DIN design to allow
for minimum space utilization on panels. All controllers are equipped
with two electromechanical relays; SPDT (Form C) contacts; UL rated 5A 115/230 Vac, 5A @ 30 Vdc resistive. Pr od. No. Description Price P33A1NN pH/ORP analyzer $680.00C33A1NN Contacting conductivity/ resistivity analyzer 680.00E33A1NN Electrodeless conductivity analyzer 680.00 (also measures % concentration or TDS) D33A1NN Dissolved Oxygen analyzer for use 1,130.00 with Hach/GLI membrane D.O. sensors F33A1NN Flow monitor/ totalizer (with four sensor 840.00 inputs, two relays, and two pulsed outputs)

Popular models shown. For other model configurations, call 800-227-4224 or visit www.hach.com.

Specifications*

Enclosure Accuracy (Controller) Polycarbonate enclosure with IP65 front panel;general purpose; two brackets for panel mounting P33, C33, F33: 0.1% of spanD33: 0.1% of span E33: 0.5% of span Ambient Conditions Operational: -4 to 140ѺF (-20 to 60C); 0 to 95%relative humidity, non-condensingStorage: -22 to 158ںF (-30 to + 70 C); 0 to 95%relative humidity, non-condensing Stability Dimensions P33, C33: 0.05% of span per 24 hours., non-cumulativeE33: 0.2% of span per 24 hours., non-cumulative 1/4 DIN; 94 x 94 x 142 mm (3.7 x 3.7 x 5.6 in.) Weight Power Requirements 0.8 kg (1.7 lbs.) Repeatability 90-130 Vac, 50/60 Hz. (10 VA max.) or 190-260 Vac, 50/60 Hz. (10 VA max) Certifications P33, C33, E33: 0.1% of span or betterD33, F33: ڱ0.05% of span cETL (pending) Display Measurement Temperature Drift Two-line by 16 character backlit LCD pH/ (ORP), P33 P33, C33: Zero & Span: < 0.03% of span per C
E33: Zero & Span: 0.02% of span per ں CF33: Zero & Span: 0.02% of span per Ѻ C Outputs Two isolated 0/4 20 mA outputs; each with 0.004 mA (12 bit) resolution and drive capability of
600 ֢Ħ load -2.0 to 14.0 pH/(-2100 to +2100 mV) Control Contacting Conductivity , C33 High/low phasing, setpoint, deadband, overfeed timer, off/on delay S/cm: 0-2.000 or 0-20.0, 0-200.0 or 0-2000;mS/cm: 0-2.000, 0-20.00, 0-200.0
Resistivity: 0-19.99 M բĦ cm or 0-999.9 K עĦ cmTDS: 0-9999 ppm or 0-9999 ppb Alarms Inductive Conductivity Low/high alarm point and low/high alarm pointdeadband, off/on delay , E33 >
*Subject to change without notice. ׵S/cm: 0-200.0 or 0-2000; mS/cm: 0-2.000, 0-20.00, or 0-2000; S/cm: 0-2.000
% Concentration: 0-99.99% or 0-200.0%TDS: 0-9999 ppm Communication (Optional) HART Protocol: Configure and measure data formultiple analyzers using HART enabled datasystem or hardware Dissolved Oxygen, D33 Memory Backup (non-volatile) 0-99.99 ppm, 0-99.99 mg/L or 0-999.9% saturation All user settings are retained indefinitely in memory(EEPROM) Paddle Wheel Flow , F33 Mounting configurations Flow rate: 0-9999, 0-999.9 or 0-99.99 withselectable flow rate units and multiplier
Volume: 0-999,999,999 with selectable volume units Panel mounting >

Find it here Buy it today on www.hach.com

395 U.S. customers only.

Controllers
  1. P. 1

  2. P. 6

    sc100 Digital Controller Plug and play up to 2 Hach digital sensors One Controller for One or Two Sensors >The Hach sc100 Controller receives data...
  3. P. 7

    sc100 Digital Controller When combined with the Hach sc100ٙ and sc1000 digitalcontrollers, the Hach family of digital sensors/analyzers gives youreliable...
  4. P. 8

    si792 2-wire Transmitter
  5. P. 9

    si792 2-wire Transmitter Password-Protected Access Controllers Separate passwords can be set for the following: Sensor CalibrationՕ Transmitter...
  6. P. 10

    Model 53 Controller pH/ORP, Conductivity, Dissolved Oxygen, Flow, Turbidity 1/2 inch Graphic Dot Matrix Backlit LCD With MultipleLanguage CapabilitiesՕ...
  7. P. 11

  8. P. 12

    Pro-Series 2-Wire Transmitter pH/ORP, Conductivity, Dissolved Oxygen, Flow LCD With Multiple Language CapabilitiesՕ Menu-Guided Operation Sensor...
Text version

All Hach catalogues and technical brochures

  1. Flow

    22 Pages

    En
  2. Process (4)

    14 Pages

    En
  3. Process (3)

    18 Pages

    En
  4. Process (2)

    24 Pages

    En
  5. Process (1)

    16 Pages

    En
  6. Lab Supplies (4)

    16 Pages

    En
  7. Lab Supplies (3)

    16 Pages

    En
  8. Lab Supplies (2)

    18 Pages

    En
  9. Lab Supplies (1)

    16 Pages

    En
  10. Parameters (3)

    26 Pages

    En
  11. Parameters (2)

    24 Pages

    En
  12. Parameters (1)

    28 Pages

    En
  13. Sample Cells

    8 Pages

    En
  14. Meters & Probes

    26 Pages

    En