You may also be interested in
Positioning stage, Synchronous linear motor, Asynchronous linear motor, Positioning table, Guide
Text version of the page
C'Bored & Thru Holes For a "B" Screw "C" Threaded Mounting Holes Power and HallEffect Cable "A" Threaded Mounting HolesH W A B CBLDA 0.82" [20.8 mm] 2.05" [52.1 mm] 4-40 [M3] 6-32 [M3] 6-32 [M3] BLDB 1.20" [30.5 mm] 2.25" [57.2 mm] 6-32 [M3] 8-32 [M4] 8-32 [M4] BLDC 1.35" [34.3 mm] 3.40" [86.4 mm] 10-32 [M5] 10-32 [M5] 10-32 [M5]Complete H2W PDF Catalog - 15422 L = Lc + Stroke (Must be a multiple of 1.20" [30.48 mm])Model #Kplbs/amp [N/amp]F contlbs [N]F peaklbs [N]I campsI pampsVeV/in/s V/m/sRcohmsLmHenryLcIn [mm]CoilWeightlbs [Kg] BLDA-012.0 [9]5 [22]15 [67]2.57.50.25 [9.85]3.813.20 [81.3]0.27 [0.12] BLDA-024.0 [8]10 [44]30 [134]2.57.50.50 [19.7]7.625.60 [142.2]0.48 [0.22] BLDB-026.0 [27]14 [62]30 [133]2.350.50 [19.7]11.84.85.60[142.2]0.60 [0.27] BLDB-039.0 [40]19 [85]45 [200]2.150.75 [29.6]17.77.28.00 [203.2]0.86 [0.39] BLDC-029.0 [40]25 [111]80 [356]2.8100.90 [35.4]8.665.60 [142.2]1.22 [0.55] BLDC-0313.5 [60]36 [160]120 [534]2.7101.35 [53.2]12.998.00 [203.2]1.75 [0.79] BLDC-0418.0 [80]47 [209]160 [712]2.6101.8 [70.9]17.21210.40 [264.2]2.27 [1.03] BLDC-0522.5 [100]59 [262]200 [890]2.6102.20 [86.6]21.51512.80 [325.1]2.80 [1.27] BLDC-0627.0 [120]71 [315]240 [1068]2.6102.60 [102.3]25.81815.20 [386.1]3.36 [1.53]F cont = Continuous Force, F peak = Peak Force @ 10% DutyKp = Force Constant, I c = Continuous Current, I p = Peak Current @ 10 % Duty Required DC Bus Voltage for Amplifier; V required = (I peak x Rc x 1.4) +(Back EMF x Velocity) H2W Technologies, Inc 28310C Ave Crocker Valencia, CA 91355 USA(888)-702-0540 (661)-702-9346 Ph (661)-702-9348 Faxwww.h2wtech.com info@h2wtech.com |
|