HY-OPTIMA™ 730 Process Hydrogen Analyzer - H2scan - #1

/ 1


catalogue search
HY-OPTIMA™ 730 Process Hydrogen Analyzer - H2scan
P. 01
Page:
HY-OPTIMA™ 730 Process Hydrogen Analyzer - H2scan


See other catalogues for H2scan

Text version of the page
HY-OPTIMA™ 730 Process Hydrogen Analyzer • CO and H2S Tolerance Description H2scan’s Series 700 in-line, real-time hydrogen specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 730 is a solid-state sensor configured to operate in background gas streams having carbon monoxide concentrations up to 100 ppm, sulfur stream concentrations up to 100 ppm, up to 95% relative humidity, and temperatures up to 100ºC. The HY-OPTIMA™ 730 is ideal for hydrogen production and petrochemical applications where real-time measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability. Operating Conditions Process Gas Tolerance: CO tolerance < 100 ppm H2S tolerance < 100 ppm Operating Humidity: 0% to 95% RH Flow Rate: 0.1 slpm to 50 slpm Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge Process Gas Temperature Range: -20ºC to 100ºC Operating Temperature Range: -20ºC to 40ºC Storage Temperature Range: -40ºC to 50ºC Calibration Background Gas: Nitrogen Adapter Fittings ½ in. MNPT thread ½ in. FNPT thread -8 SAE/MS thread size ... and many other industry standards Dimensions Total Length: 9.1 in. Length of Enclosure: 6.7 in. Length of Tube: 2.4 in. Width: 3.4 in. Depth: 1.4 in. Certifications: . Performance Hydrogen Sensitivity Range: 0.5% to 100% hydrogen at 1 ATM on a volume basis in a single or multi-component gas background Typical Response Time: T90 less than 30 sec Ingress Protection: IP64 capable Recommended Verification Interval: 90 days Product Life Expectancy: 10 years Accuracy(*): ± 0.15% absolute for 0.5 to 10% H2 ± 0.50% absolute for 10 to 100% H2 Drift/week: ± 0.10% absolute for 0.5 to 10% H2 ± 0.20% absolute for 10 to 100% H2 Repeatability: ± 0.10% absolute for 0.5 to 10% H2 ± 0.20% absolute for 10 to 100% H2 Linearity: ± 0.10% absolute for 0.5-10% H2 ± 0.20% absolute for 10-100% H2 Interface Options Input Voltage Range: 8 VDC to 13 VDC Input Current: 1.0 A Analog Outputs: Output Voltages - OR - Output Currents • 0 VDC to 5 VDC • 4 mA to 20 mA • 1 VDC to 5 VDC • 0 mA to 20 mA • 0 VDC to 4 VDC • User-specific mA range • 0.5 VDC to 4.5 VDC • User-specific VDC range Serial Communication Options: RS232 or RS422 Relay Contacts: Two programmable 60 VDC / 1 A SPDT relays with both normally open (N.O.) and normally closed (N.C.) contacts HY-OPTIMA™ is a registered Trademark of H2scan. Specifications subject to change without prior notice. H2scan Sept. 2009, International Release 90000017 R4 28486 Westinghouse Place, Ste.100, Valencia, CA 91355 Tel: 661-775-9575, Fax: 661-775-9515 Email: sales@h2scan.com Website: www.h2scan.com Sensor performance specifications are only valid for units configured for a maximum 65ºC dry process stream temperature. All figures assume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The accuracy is specified for serial port output only.

pageCatalog pdf di En 2012-02-06-10