HYDROGEN SPECIFIC MEASUREMENT SOLUTIONS Hydrogen is the future, we can sense it! 27215 Turnberry Lane, Unit A

 Open the catalogue to page 1

HY-OPTIMA™ 700B Series Operating Manual MISSION STATEMENT Our Mission Deliver unsurpassed value and optimize green initiatives with our one of a kind continuous hydrogen-specific sensing technology worldwide. Our Value Propositions Enable end-user customers to efficiently and effectively optimize:  Electric utility power transformer fleet and other oil-filled assets (Grid) Petroleum refinery and other industrial process control Facility and equipment safety to minimize downtime ...at a much lower total costs of ownership than the competition. Our Strategic Objectives H2scan's technology accepted...

 Open the catalogue to page 2

HY-OPTIMA™ 700B Series Operating Manual

 Open the catalogue to page 3

HY-OPTIMA™ 700B Series Operating Manual

 Open the catalogue to page 4

HY-OPTIMA™ 700B Series Operating Manual IMPORTANT NOTICES Read and understand this operating manual before installing or using the unit. Only use cables from H2scan with this unit. If this equipment is used in a manner not specified by H2scan, the protection provided by this equipment may be impaired. Hydrogen is flammable at 4% in air. Take indications seriously and be prepared to take action. In the event of detection of 4% or higher of a hydrogen gas concentration there is a high probability of a hazard to safety. Inform local emergency response personnel immediately. Do not apply power to...

 Open the catalogue to page 5

HY-OPTIMA™ 700B Series Operating Manual Chapter 1: Model Specifications and Certifications 1.1 Description The HY-OPTIMA™ 700B Series In-line Hydrogen Process Analyzer is designed to detect and/or measure hydrogen using a solid-state, non-consumable sensor that is configured to operate in process gas streams. The H2scan thin film technology provides a direct hydrogen measurement that is not cross sensitive to other gases. The hydrogen specific solid-state sensing element is designed for ease of use, interface flexibility and true process control. The analyzer contains all the circuitry necessary...

 Open the catalogue to page 6

HY-OPTIMA™ 700B Series Operating Manual The HY-OPTIMA 710B Process Hydrogen Analyzer has been specifically manufactured to operate in low hydrogen conditions with increased accuracy.  0.1% to 20% hydrogen by volume at 1.0 atm 0.1% to 10% hydrogen by volume at 2.0 atm The HY-OPTIMA inert background. 720B Process Hydrogen Analyzer has been specifically manufactured to operate in an air or Operation in background streams in which H2 is not typically present Calibration Background Gas: Air or Inert Hydrogen Sensitivity Range: o 10% to 125% hydrogen lower flammability limit Note: Please disregard...

 Open the catalogue to page 7

HY-OPTIMA™ 700B Series Operating Manual Linearity (absolute) Drift / week (absolute) 10% to 100% H2 Accuracy (absolute) Hydrogen Range 710B products operated at 15 psig will have a reduced H2 range of 0.1% - 10% H2. 720B products may be operated in an Air, O2, or N2 backgrounds. Sensor performance specifications assume a dry process stream, an ambient temperature of 25°C, pressure compensation and are in addition to any errors in the pressure reading and calibration gases used. The accuracy is specified for the serial port output only. See Section 4.2.1 – Background Gases for a list of approved...

 Open the catalogue to page 8

HY-OPTIMA™ 700B Series Operating Manual UL 61010-1 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 1: General Requirements - Edition 2 Revision Date 2008/10/28 CSA C22.2 NO. 61010-1 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use — Part 1: General Requirements Edition 2 - Revision Date 2008/10/01 EN61326-1:2006 Electrical equipment for measurement, control and laboratory use EMC requirements - Part 1: General requirements EN55011 Industrial, scientific and medical (ISM) radio-frequency equipment Electromagnetic...

 Open the catalogue to page 9

HY-OPTIMA™ 700B Series Operating Manual SERIAL COMMUNICATION (OPTIONAL) RELAY (OPTIONAL) POWER & ANALOG

 Open the catalogue to page 10

HY-OPTIMA™ 700B Series Operating Manual Chapter 2: Installation 2.1 Analyzer Location The analyzer can be mounted in any orientation or position. Mounting the analyzer above the process connection is preferred, especially in process streams containing liquids or potentially condensing gases. Mounting the sensor pointing upwards is not recommended, as debris, condensation, or other contaminants can accumulate in the sensor. 2.2 Wiring / Connections 2.2.1 Power / Analog Output Supplied Cable – 4m (13 ft.) Other lengths are available. Wire Color Brown White Black Blue Description Power Power Return...

 Open the catalogue to page 11

HY-OPTIMA™ 700B Series Operating Manual 2.2.3 Serial Interface Supplied Cable – 4m (13 ft.) Other lengths are available. Wire Color Brown White RS232 (standard) Description DB9 Pin +6V (N.C.) TxD (Device Transmit) 3 TxD- (Device Transmit, Negative) TxD+ (Device Transmit, Positive) RxD- (Device Receive, Negative) RxD+ (Device Receive, Positive) Ground 2.3 Process Connection H2scan offers a variety of fittings to mate the analyzer to a process stream. The following table lists our standard fitting selections. Others are available upon request. ½ in. MNPT thread ½ in. FNPT thread -8 SAE/MS thread...

 Open the catalogue to page 12

HY-OPTIMA™ 700B Series Operating Manual 2.5 Mounting Mounting is achieved by securing the sensor tube into the supplied fitting directly in the process piping as shown below. H2scan recommends the housing be mounted vertically to prevent condensation from affecting the sensor with connectors on top and the sensor tube pointing downwards. Optional mounting brackets that attach to the instrument housing are also available. WARNING: Do not cinch down or tighten ferrules outside of the Ferrule Region of the long tube or you will risk permanently damaging the long tube and sensor assembly within. 1.0...

 Open the catalogue to page 13

HY-OPTIMA™ 700B Series Operating Manual If the analyzer is being turned on from an off position, power on the analyzer before flowing gas across the sensor. The sequence of steps which are to be followed is: 1. Power on the analyzer and wait for the 5 minute warmup routine to complete. The status LED will be amber in color during warm-up and will change to green when the analyzer is ready. The following operations will be completed in this warm-up sequence:  Heat the sensor to operating temperature Perform the Power-On-Self-Test (POST) Apply a gas concentration of at least 5% (and not exceeding...

 Open the catalogue to page 14