HYDROGEN SPECIFIC MEASUREMENT SOLUTIONS Hydrogen is the future, we can sense it! 27215 Turnberry Lane, Unit A

 Open the catalogue to page 1

HY-OPTIMA™ 2700 Series Operating Manual MISSION STATEMENT Our Mission Deliver unsurpassed value and optimize green initiatives with our one of a kind continuous hydrogen-specific sensing technology worldwide. Our Value Propositions Enable end-user customers to efficiently and effectively optimize:  Electric utility power transformer fleet and other oil-filled assets (Grid) Petroleum refinery and other industrial process control Facility and equipment safety to minimize downtime ...at a much lower total costs of ownership than the competition. Our Strategic Objectives H2scan's technology accepted...

 Open the catalogue to page 2

HY-OPTIMA™ 2700 Series Operating Manual

 Open the catalogue to page 3

HY-OPTIMA™ 2700 Series Operating Manual

 Open the catalogue to page 4

HY-OPTIMA™ 2700 Series Operating Manual IMPORTANT NOTICES Read and understand this operating manual before installing or using the unit. Only use cables from H2scan with this unit. If this equipment is used in a manner not specified by H2scan, the protection provided by this equipment may be impaired. Hydrogen is flammable at 4% in air. Take indications seriously and be prepared to take action. In the event of detection of 4% or higher of a hydrogen gas concentration there is a high probability of a hazard to safety. Inform local emergency response personnel immediately. Do not apply power to...

 Open the catalogue to page 5

HY-OPTIMA™ 2700 Series Operating Manual Chapter 1: Model Specifications and Certifications 1.1 Description The HY-OPTIMA™ 2700 Series, Explosion Proof In-line Hydrogen Process Analyzer is designed to detect and/or measure hydrogen using a solid-state, non-consumable sensor that is configured to operate in process gas streams. The H2scan thin film technology provides a direct hydrogen measurement that is not cross sensitive to other gases. The hydrogen specific solid-state sensing element is designed for ease of use, interface flexibility and true process control. The analyzer contains all the...

 Open the catalogue to page 6

HY-OPTIMA™ 2700 Series Operating Manual The HY-OPTIMA 2710 Process Hydrogen Analyzer has been specifically manufactured to operate in low hydrogen conditions with increased accuracy.  0.1% to 20% hydrogen by volume at 1.0 atm 0.1% to 10% hydrogen by volume at 2.0 atm The HY-OPTIMA inert background. 2720 Process Hydrogen Analyzer has been specifically manufactured to operate in an air or Operation in background streams in which H2 is not typically present Calibration Background Gas: Air or Inert Hydrogen Sensitivity Range: o 10% to 125% hydrogen lower flammability limit Note: Please disregard...

 Open the catalogue to page 7

HY-OPTIMA™ 2700 Series Operating Manual Linearity (absolute) Repeatability (absolute) Drift / week (absolute) Accuracy (absolute) Hydrogen Range 2710 products operated at 15 psig will have a reduced H2 range of 0.1% - 10% H2. 2720 products may be operated in an Air, O2, or N2 backgrounds. Sensor performance specifications assume a dry process stream, an ambient temperature of 25°C, pressure compensation and are in addition to any errors in the pressure reading and calibration gases used. The accuracy is specified for the serial port and digital display output only. See Section 4.2.1 – Background...

 Open the catalogue to page 8

HY-OPTIMA™ 2700 Series Operating Manual 1.4 Analyzer Certifications UL: Class I, Division 1, Groups B, C, and D Hazard Class Area Classification Hazard Class: Class I Flammable Gases Division: Group B Group C Group D Protection Methods: Hydrogen Ethylene Propane Applicable Certification Documents: UL 1203 (U.S.) CSA-30 (Canada) UL 1203 - STANDARD FOR EXPLOSION-PROOF AND DUST-IGNITION-PROOF ELECTRICAL EQUIPMENT FOR USE IN HAZARDOUS (CLASSIFIED) LOCATIONS Division I Explosion-proof Enclosures UL 508 - STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT CSA-C22.2 NO. 30-M1986 – EXPLOSION-PROOF ENCLOSURES FOR...

 Open the catalogue to page 9

HY-OPTIMA™ 2700 Series Operating Manual

 Open the catalogue to page 10

HY-OPTIMA™ 2700 Series Operating Manual Safety Information All cable entry devices, conduit sealing devices, and blanking elements shall be certified in type of explosion protection flameproof enclosure “d”, suitable for the conditions of use and correctly installed. Conduit sealing fittings must be installed within 18” of the analyzer. Unused apertures shall be closed with suitable blanking elements. Field wiring shall be suitable for at least 80ºC. For ambient temperatures below -10ºC use field wiring suitable for minimum ambient temperature. WARNING: H2scan’s HY-OPTIMA™ 2700 Series Explosion...

 Open the catalogue to page 11

HY-OPTIMA™ 2700 Series Operating Manual If the cable is accidentally unplugged, plug it into the connector marked “INTF” (See Figure 2). Plugging it into any other connector will damage the Display Board and the Sensor Board. Figure 2: Display Connections After wiring is complete (see Section 2.2 Wiring), reinsert the Display Board into the posts. Further disassembling the analyzer voids the warranty and could cause serious damage. The board directly beneath the Display Board is the Interface Board. DO NOT disconnect the Interface Board. 2.2 Wiring All wiring is done on the Interface Board (Figure...

 Open the catalogue to page 12

HY-OPTIMA™ 2700 Series Operating Manual 1. Insert wires through the conduit connections. 2. Strip the insulation off the wires and make the connections to the connector block. 3. Plug the connector into the receptacle. 4. Pull any excess wire out of the enclosure.

 Open the catalogue to page 13

HY-OPTIMA™ 2700 Series Operating Manual 2.2.1 AC Power Wiring Power Board: J2 4-Pin Terminal Block for the Power Cable Pin Number Alternating current return CHASSIS GROUND Safety connection to ground SIGNAL GROUND Common ground for sensitive circuitry isolated from chassis ground. If a signal ground is not available, short this pin with the chassis ground. Some facilities have separate grounds for signal and AC power. If this is the case run the signal ground and chassis ground wires to the appropriate locations. If there is one ground, jumper the chassis ground and signal ground pins together...

 Open the catalogue to page 14

HY-OPTIMA™ 2700 Series Operating Manual 2.2.4 4-20mA Interface Wiring Interface Board: J5 2-Pin Terminal Block for Output Cable Pin Number Hydrogen Level Power-On Self Diagnostic The analog output range can be changed in the field. Please refer to Section 3.4 Analog Output. 2.2.5 Serial Interface Wiring Interface Board: J4 5-Pin Terminal Block for Serial Interface Cable J3 Pin TxD- (Device Transmit, Negative) TxD+ (Device Transmit, Positive) RxD- (Device Receive, Negative) RxD+ (Device Receive, Positive) Signal Ground 2.3 Relays Relay 1. Alert 2. Alarm 3. Fault Usage A warning that the hydrogen...

 Open the catalogue to page 15