HY-OPTIMA 1700 Series Intrinsically Safe In-line Hydrogen Process Analyzer - 1 Pages

  1. P. 1

Catalogue excerpts

HY-OPTIMA 1700 SERIES DATA SHEET Hydrogen is the future, we can sense it! TM ATEX Intrinsically Safe In-line Hydrogen Process Analyzer H2scan’s HY-OPTIMATM 1700 series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMATM 1700 series is an ATEX certified Intrinsically Safe (IS) device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 60°C. The HY-OPTIMATM 1700 series is ideal for process gas applications where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability. Configuration Details HY-OPTIMA 1700 Series 90 Days Product Life Expectancy Field Calibration Operating Humidity Flow Rate Operating Temperature Storage Temperature Output Signals Analog Serial Input Voltage Power Barrier Power Barrier Range Intrinsically Safe Sensor Sensor Range Input Power Safety Certifications Adapter Fitting 0359 II 1 G, Ex ia II H2, d+d IIB T3 Ga (Probe Tip) II 2 G, Ex ib II H2, ib d IIB T3 Gb (Analyzer Body) ITS07ATEX25634X N2, CO2, Alkanes (CH4), Inert Gases (He, Ar) Verification Interval Product Selection Hydrogen Range The HY-OPTIMATM 1700 Series product family includes sensor types that are designed for specific hydrogen ranges, corrosive gas tolerances and operation when no hydrogen is present. See the guide below for more details. 1740 0.5% to 100% Yes 20% 3% 3 2 30 < 90 0.3% 1.0% 0.2% 0.4% 0.2% 0.4% 0.2% 0.4% N2 1. 1720 products may be operated in an Air, O2 or N2 backgrounds (see manual). 2. Sensor performance specifications assume a dry process stream, an ambient temperature of 25°C, pressure compensation and are in addition to any errors in the calibration gases used. The accuracy is specified for the serial port and digital display output only. 3. Up to 10% H2S resistant product available with special conditioning charge on request. HY-OPTIMATM is a registered Trademark of H2scan Specifications subject to change without prior notice Doc # 90000144 R0 27215 Turnberry Lane, Unit A, Valencia CA., 91355 Tel: 661-775-9575, Fax: 661-775-9515 Email: sales@h2scan.com, Website: w

 Open the catalogue to page 1

All H2scan catalogues and technical brochures

Archived catalogues

  1. H2scan Brochure

    7 Pages

    En