HY-OPTIMA™ 1700 Intrinsically Safe Process Hydrogen Analyzer - H2scan - #1

/ 2


catalogue search
HY-OPTIMA™ 1700 Intrinsically Safe Process Hydrogen Analyzer - H2scan
P. 01
HY-OPTIMA™ 1700 Intrinsically Safe Process Hydrogen Analyzer - H2scan
P. 02
Pages:
HY-OPTIMA™ 1700 Intrinsically Safe Process Hydrogen Analyzer - H2scan


See other catalogues for H2scan

Text version of the page
Description HY-OPTIMA™ 1700 Intrinsically Safe Process Hydrogen Analyzer H2scan’s HY-OPTIMATM 1700 in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 1700 is an intrinsically safe device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to100ºC. The HY-OPTIMA™ 1700 is ideal for process gas streams containing virtually no contaminants and where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability. Performance Hydrogen Sensitivity Range: 0.5% to 100% hydrogen by volume at 1 ATM Response Time: T90 < 30 sec Ingress Protection: IP64 capable Recommended Verification Interval: 90 days Product Life Expectancy: 10 years Accuracy(*): ± 0.3% absolute for 0.5 to 10% H2 ± 1.0% absolute for 10 to 100% H2 Drift/week: ± 0.2% absolute for 0.5 to 10% H2 ± 0.4% absolute for 10 to 100% H2 Repeatability: ± 0.2% absolute for 0.5 to 10% H2 ± 0.4% absolute for 10 to 100% H2 Linearity: ± 0.2% absolute for 0.5-10% H2 ± 0.4% absolute for 10-100% H2 Interface Options Power Barrier Input Voltage: 24 VDC nominal Power Barrier Input Voltage Range: 20 VDC to 28 VDC Intrinsically Safe Sensor Input Voltage: 10 VDC Sensor Input Voltage Range: 5 VDC to 28 VDC Input Power: 10 W Analog Output: 4 mA to 20 mA Serial Communication: RS422 Certifications 0359 II 1 G, Ex ia II H2, d+d IIB T3 II 2 G, Ex ib II H2, ib d IIB T3 ITS07ATEX25634X Operating Conditions Operating Humidity: 0% to 95% RH Flow Rate: 0.1 slpm to 50 slpm Pressure: 0 to 7 bar gauge, 0 to 100 psi gauge Process Gas Temperature Range: -20ºC to 100ºC Operating Temperature Range: -20ºC to 40ºC Storage Temperature Range: -40ºC to 50ºC Calibration Background Gas: Nitrogen Included Accessories Intrinsically Safe Power Barrier Armored Power / Analog Cable: 4 m Calibration Cup Optional Accessories Single Channel Intrinsically Safe Analog Output Barrier (with or without relays) Single Channel Intrinsically Safe RS422 Serial Interface Barrier Serial Interface Cable: 4 m (custom lengths available) Armored Power / Analog Cable (custom lengths available) Adapter Fittings ½ in. MNPT thread ½ in. FNPT thread -8 SAE/MS thread size … and many other industry standards Dimensions Total Length: 10.3 in. Length of Enclosure: 6.8 in. Length of Tube: 2.9 in. Width: 3.4 in. Depth: 1.4 in. Sensor performance specifications are only valid for units configured for a maximum 65ºC dry process stream temperature. All figures assume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The accuracy is specified for serial port output only. HY-OPTIMATM is a registered Trademark of H2scan. 28486 Westinghouse Place, Ste.100, Valencia, CA 91355 Specifications subject to change without prior notice. Tel: 661-775-9575, Fax: 661-775-9515 H2scan October 2009, International Release Email: sales@h2scan.com 90000010 R5 Website: www.h2scan.com

pageCatalog pdf di En 2012-05-19-13