You may also be interested in
Hydrogen detector, Analyzer, Leak detector, Hydrogen analyzer, Detector
Text version of the page
HY-ALERTATM 1600 Intrinsically Safe Area Hydrogen Monitor
HY-ALERTATM is a registered Trademark of H2scan. 28486 Westinghouse Place, Ste.100, Valencia, CA 91355
Specifications subject to change without prior notice. Tel: 661-775-9575, Fax: 661-775-9515
H2scan June 2008, International Release Email: sales@h2scan.com
90000009 R2 Website: www.h2scan.com
Description
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection
and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to
5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is
designed for either ceiling or wall mount and has an RS422 capability that extends an intrinsically safe interface from
the sensor to the controller to several hundred feet. H2scan's hydrogen-specific sensor technology has no cross
sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
Performance
Hydrogen Sensitivity Range:
0.4% to 5% hydrogen by volume
10% to 125% hydrogen lower flammable limit
Accuracy: ± (0.03 x indication + 0.2) percent
hydrogen by volume
Typical Response Time: T90 of 60 sec maximum
Ingress Protection: IP64 capable
Calibration Interval: 90 days
Product Life Expectancy: 10 years
Interface Options
Power Barrier Input Voltage: 24 VDC nominal
Power Barrier Input Voltage Range: 20 VDC to 28 VDC
Intrinsically Safe Sensor Input Voltage: 10 VDC
Sensor Input Voltage Range: 5 VDC to 28 VDC
Input Power: 10 W
Analog Output: 4 mA to 20 mA
Serial Communication: RS422
Operating Conditions
Operating Humidity: 0% to 95% RH
Operating Temperature Range: -20ºC to 40ºC
Storage Temperature Range: -40ºC to 50ºC
Calibration Background Gas: Air
Included Accessories
Intrinsically Safe Power Barrier
Armored Power / Analog Cable: 4 m
Calibration Cup
Optional Accessories
Single Channel Intrinsically Safe Analog Output Barrier
(with or without relays)
Single Channel Intrinsically Safe RS422 Serial Interface
Barrier
Serial Interface Cable: 4 m (custom lengths available)
Armored Power / Analog Cable (custom lengths
available)
Dimensions
Total Length: 8.1 in.
Total Width: 4.4 in.
Depth: 1.6 in.
Certification
0359
II 1 G, Ex ia II H2, d+d IIB T3
II 2 G, Ex ib II H2, ib d IIB T3
ITS07ATEX25634X
Figure 1 shows the hazardous area designations for this apparatus. Note that the
sensor probe tip is rated for Category 1 (Zone 0) and the electronics assembly is
rated for Category 2 (Zone 1).
|
|