HYDROGEN SPECIFIC! LEAK DETECTION Hydrogen is the future, we can sense it! 27215 Turntaerry Lane, Unit A

 Open the catalogue to page 1

Deliver unsurpassed value and optimize green initiatives with our one of a kind continuous hydrogen-specific sensing technology worldwide. Enable end-user customers to efficiently and effectively optimize: ■ Electric utility power transformer fleet and other oil-filled assets (Grid) ■ Petroleum refinery and other industrial process control ■ Facility and equipment safety to minimize downtime ...at much lower total costs of ownership than the competition. H2scan's technology accepted as the new gold standard in hydrogen sensors. H2scan's business recognized for innovation and ingenuity, high quality...

 Open the catalogue to page 2

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL

 Open the catalogue to page 3

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL

 Open the catalogue to page 4

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL IMPORTANT NOTICES Read and understand this operating manual before operating or servicing the monitor LIMITATION OF LIABILITY IN THE EVENT OF A DEFECT IN A PRODUCT, H2SCAN SHALL NOT BE RESPONSIBLE FOR ANY DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING THEREFROM, INCLUDING, BUT NOT LIMITED TO, LOSS OF REVENUE AND/OR PROFIT. Read and understand this operating manual before installing or using the monitor. Only use cables from H2scan with this monitor. If this equipment is used in a manner not specified by H2scan,...

 Open the catalogue to page 5

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL 2 DESCRIPTION The HY-ALERTA™ 2620 Explosion Proof Area Hydrogen Monitor is designed to detect and/or measure hydrogen. The hydrogen specific solid-state sensing element is designed for ease of use, interface flexibility and true process control. The electronics contains all the circuitry necessary to operate the sensor and present calibrated hydrogen readings to an analog current output and an RS232 or RS422 digital output. .

 Open the catalogue to page 6

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL 3 SPECIFICATIONS Sample Gas Flow Rate Sensor Ambient Temperature: -20°C to + 55°C Storage: -40 to +80 °C Remote Ambient Temperature: -20 to +55C Typical response time Input Power Analog Output Isolated and self-powered 0-20mA, maximum load impedance: 650Ω Relay Contacts Three programmable SPDT relays with both normally open (N.O.) and normally closed (N.C.) contacts. 5A, 240VAC MAX, General Use Accuracy - serial port output only. ± (0.03 x indication + 0.2) percent hydrogen by volume Serial Communication RS232 or RS422 19200...

 Open the catalogue to page 7

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL UL 913 - STANDARD FOR INTRINSICALLY SAFE APPARATUS AND ASSOCIATED APPARATUS FOR USE IN CLASS I, II, III, DIVISION 1, HAZARDOUS (CLASSIFIED) LOCATIONS CSA C22.2 NO. 157 - INTRINSICALLY SAFE AND NON-INCENDIVE EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS Class 1, Division 1, Groups A, B, C, and D Remote Certifications 0359 EN 60079-0:2009 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES. PT. 0, GENERAL REQUIREMENTS EN 60079-11:2007 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES. PT. 11, INTRINSIC SAFETY "i" EN 60079-26:2007...

 Open the catalogue to page 8

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL FIGURE 1: Monitor Module Dimensions

 Open the catalogue to page 9

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL 4 SETTINGS The monitor’s operational and output settings have been configured at the manufacturer as specified at the time of purchase. Settings may be changed through the serial port or the remote control. WARNING: If settings are changed from those set by the manufacturer then it is the user’s responsibility to understand the implications to the connecting equipment monitoring the monitor. 5 OPTIMUM MONITOR PERFORMANCE Verify that all electrical connections are made as recommended in section 8. Switching the polarity can...

 Open the catalogue to page 10

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL conduit to the monitor, install a device such as a pull box or pulling elbow near the monitor. Pull the wires through this then push them into the housing. The pull box and any conduit must be rated with the appropriate classification for the installation location and installed accordingly. 7 MOUNTING Mounting is achieved with two ¼ inch screws through the mounting holes in the base of the explosion proof housing. ¾ inch solid conduit threaded into the enclosure will also serve as further structural support. The housing can...

 Open the catalogue to page 11

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL 8 WIRING All wiring is done with the Interface Board. The connectors are two piece designs in which the wires are screwed into a receptacle in standard terminal block style. This is plugged into the board. INTERFACE BOARD SHOWING CONNECTORS 8.1 AC POWER WIRING Power Board: J2 4-Pin Terminal Block for the Power Cable Pin Number Alternating current return CHASSIS GROUND Safety connection to ground SIGNAL GROUND Common ground for sensitive circuitry isolated from chassis ground. Grounding Some facilities have separate grounds...

 Open the catalogue to page 12

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL Interface Board: J6 12-Pin Terminal Block for Output Cable Pin Number SPDT Relay 1 for the Alert level of hydrogen SPDT Relay 2 for the Alarm level of hydrogen SPDT Relay 3 for fault conditions 8.3 OPTIONALPRESSURE SENSOR WIRING Interface Board: J6 12-Pin Terminal Block for Output Cable Pin Number 1 to 5V pressure sensor input 8.4 4-20MA INTERFACE WIRING Interface Board: J5 2-Pin Terminal Block for Output Cable Pin Number Description 4-20mA analog output 8.5 SERIAL INTERFACE WIRING Interface Board: J4 5-Pin Terminal Block for...

 Open the catalogue to page 13

HY-OPTIMA™ 2620 Explosion Proof Area Hydrogen Monitor OPERATING MANUAL 9 STARTUP The monitor is designed to be exposed to an air background gas with no hydrogen most of the time. For optimal performance keep any hydrogen exposure to the sensor to less than one hour. If the hydrogen exposure exceeds this time, the sensor may need to be reconditioned by leaving it powered on in air for a few days. 9.1 OPTIONAL PRESSURE SENSOR If the pressure sensor was not installed and configured at H2scan the “PS” command must be used to setup the pressure sensor. (See section 14.10 PS COMMAND) If the sensor was...

 Open the catalogue to page 14