You may also be interested in
Analyzer, Detector, Hydrogen analyzer, Hydrogen detector, Leak detector
Text version of the page
HY-ALERTATM 2600 Explosion Proof Area Hydrogen Monitor
HY-ALERTA™ is a registered Trademark of H2scan. 28486 Westinghouse Place, Ste.100, Valencia, CA 91355
Specifications subject to change without prior notice. Tel: 661-775-9575, Fax: 661-775-9515
H2scan 2007, International Release Email: sales@h2scan.com
90000021 R2 Website: www.h2scan.com
Description
H2scan’s HY-ALERTA™ 2600 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection
and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to
5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s lower flammability limit. The monitor is
designed for either ceiling or wall mount and has an RS422 capability that extends the interface from the Sensor
Module to the Control Module to several hundred feet. H2scan's hydrogen-specific sensor technology has no cross
sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
Performance
Hydrogen Sensitivity Range:
0.4% to 5.0% hydrogen by volume
10% to 125% hydrogen lower flammable limit
Accuracy: ± (0.03 x indication + 0.2) percent
hydrogen by volume
Typical Response Time: T90 of 60 sec maximum
Ingress Protection: IP66
Calibration Interval: 90 days
Product Life Expectancy: 10 years
Interface Options
Input Voltage Range: 90 VAC to 260 VAC
Input Power: 15 W
Analog Output: 4 mA to 20 mA
Serial Communication: RS422
Relay Contacts: Two programmable 5 A, 250 VDC / VAC
SPDT relays with both normally open (N.O.) and
normally closed (N.C.) contacts
HY-ALERTATM 2600 Includes…
Sensor Module
Control Module
Infrared Remote Control
Operating Conditions
Operating Temperature Range: 4ºC to 60ºC
Storage Temperature Range: -40ºC to 50ºC
Calibration Background Gas: Air
Dimensions
Sensor Module
Width: 13.8 cm (5.4 in.)
Length: 19.3 cm (7.6 in.)
Depth: 13.0 cm (5.1 in.)
Control Module
Width: 13.8 cm (5.4 in.)
Length: 14.3 cm (5.6 in.)
Depth: 14.4 cm (5.7 in.)
Explosion Proof Housing Certifications (pending)
Class I Group B, C, D; Class II Group E, F, G; Class III Type 4X
Class I Zone 1 AEx d IIC
Ex d IIC IEC 60529 IP66
|
|