H >
2 ECOnomy’s ProFC™ series PEM fuel cell stacks are designed for demonstration and study of fuel cell operation. Data Sheet Parameters by model >
Model (No. of cells is indicated by the last digit) Nominal Power Approximate Dimensions Recommended gas pressures (w/o bolts, fittings, and current collectors) (bar, gauge) Recommended gas flow rates (SLPM) H 2 O 2 H 2 O 2 ProFC-1 12 W @ 0.6 V 13 x 13 x 3 cm 1.0 1.2 0.15 0.25 ProFC-2 23 W @ 1.2 V 13 x 13 x 3.5 cm 1.0 1.2 0.3 0.4 ProFC-3 34 W @ 1.8 V 13 x 13 x 3.8 cm 1.0 1.2 0.45 0.6 ProFC-4 45 W @ 2.4 V 13 x 13 x 4 cm 1.2 1.4 0.6 0.8 ProFC-5 55 W @ 3.0 V 13 x 13 x 4.5 cm 1.2 1.4 0.7 1.0 ProFC-6 66 W@ 3.6 V 13 x 13 x 5 cm 1.4 1.5 0.85 1.15 ProFC-7 76 W@ 4.2 V 13 x 13 x 5.5 cm 1.5 1.7 1.0 1.35 ProFC-8 85 W@ 4.8 V 13 x 13 x 6 cm 1.5 1.7 1.1 1.5 ProFC-9 94 W@ 5.4 V 13 x 13 x 6.5 cm 1.7 1.8 1.2 1.65 ProFC-10 100 W@ 6.0 V 13 x 13 x 7 cm 1.8 1.9 1.3 1.75 General operational parameters and conditions Maximum output voltage (w/o load) 0.9 V per cell >
*
Maximum gas pressures (each channel) 2 bar gauge Allowable pressure difference between the two channels 0.1-0.4 bar >
**
Acceptable ambient temperature 0 to +50 C Stack working temperature 50-70 C Stack maximal temperature Up to 80 C Fuel / Oxidant Hydrogen / Oxygen Optimal working conditions for achieving nominal output. 99.99% (or more) purity of H >
2 and O >
2 , 100% humidity of gases >
***
* It is strongly recommended to keep the loaded voltage higher than 0.5V on each cell. ** O 2 pressure must always be 0.1-0.4 bar higher than H 2 pressure, and the flow rate of O 2 must be greater than 100 ml/min. *** Operation at lower temperatures, lower humidity of gases or with air instead of oxygen is also possible, although with loss of performance.